Содержание cRIO-9039

Страница 1: ...erutilized and idle equipment along with credit for buybacks and trade ins Custom engineering so your equipment works exactly as you specify Critical and expedited services Leasing Rentals Demos In st...

Страница 2: ...nchronization capabilities of NI cRIO 9039 Sync visit ni com info and enter the Info Code cRIO9039sync USB 2 0 Host Port USB 2 0 Device Port 2 GB DDR3L RJ 50 RS 232 Serial Port RJ 50 RS 485 422 DTE Se...

Страница 3: ...ation 33 Resetting the System CMOS and BIOS Settings 33 Power On Self Test Warning Messages 34 BIOS Setup Utility 34 Main Setup Menu 35 Advanced Setup Menu 36 Boot Setup Menu 37 Save Exit Menu 39 Worl...

Страница 4: ...ng DHCP 1 Disable secondary network interfaces on the host computer such as a wireless access card on a laptop 2 Ensure that any anti virus and firewall software running on the host computer allows co...

Страница 5: ...onfigure IPv4 Address control e Enter values for IPv4 Address Subnet Mask Gateway and DNS Server based on the information you recorded Be sure to enter a value for IPv4 Address that is not used by ano...

Страница 6: ...ns from running Disable FPGA Startup App Rebooting the cRIO 9039 with this setting on prevents autoloading of any FPGA application Enable Secure Shell SSH Logins Rebooting the cRIO 9039 with this sett...

Страница 7: ...5 422 DTE Serial Port 6 Mini DisplayPort 7 USB Host Ports 8 USB Device Port RJ 45 Gigabit Ethernet Ports The cRIO 9039 has two tri speed RJ 45 Gigabit Ethernet ports By default both Ethernet ports are...

Страница 8: ...e following NI Ethernet cables are available for the cRIO 9039 Table 3 RJ 45 Gigabit Ethernet Cables Cables Length Part Number CAT 5E Ethernet Cable shielded 2 m 151733 02 5 m 151733 05 10 m 151733 10...

Страница 9: ...1 input If the input voltage to V1 is insufficient the cRIO 9039 operates from the V2 input The cRIO 9039 has reverse voltage protection The following NI power supplies and accessories are available f...

Страница 10: ...t Note Screw the slot cover closed completely Tighten the captive screws to a maximum torque of 0 75 N m 6 7 lb in using a 1 Phillips screwdriver Do not overtighten RS 232 Serial Port The cRIO 9039 ha...

Страница 11: ...on Modular Plug to 9 Pin DSUB 1 m 182845 01 2 m 182845 02 3 m 182845 03 RS 485 422 DTE Serial Port The cRIO 9039 has an RS 485 422 DTE serial port that is implemented with an RJ 50 10 position modular...

Страница 12: ...Number RS 485 S8 Serial Cable 10 Position Modular Plug to 9 Pin DSUB Isolated 1 m 184428 01 Mini DisplayPort Use the Mini DisplayPort to connect a monitor and implement a local HMI You can use a singl...

Страница 13: ...ni DisplayPort to Full DisplayPort Native Cable 0 5 m 157232 0R5 1 m 157232 01 2 m 157232 02 Mini DisplayPort to VGA Adapter Cable 0 5 m 157230 0R5 Mini DisplayPort to DVI Adapter Cable 0 5 m 157231 0...

Страница 14: ...age 20 Installing a Ferrite on the USB Cables You must install a ferrite around all USB cables connected to the USB host ports to ensure that the cRIO 9039 meets all EMC standards applicable to your c...

Страница 15: ...e cRIO 9039 is in a hazardous location or connected to high voltages If the cRIO 9039 is not in a hazardous location you can connect and disconnect USB devices without affecting operation The followin...

Страница 16: ...r 5 seconds and then release it to boot the controller in safe mode and enable Console Out 2 Hold the RESET button again for 5 seconds to boot the controller into safe mode enable Console Out and rese...

Страница 17: ...cRIO 9039 LEDs 5 4 1 2 3 6 1 POWER LED 2 STATUS LED 3 USER1 LED 4 USER FPGA1 LED 5 Gigabit Ethernet LEDs 6 SD LEDs POWER LED Indicators The following table lists the POWER LED indicators Table 16 POWE...

Страница 18: ...longer than five seconds or by enabling safe mode in MAX Refer to the Measurement Automation Explorer MAX Help for information about safe mode Blinks four times and pauses The cRIO 9039 is in safe mod...

Страница 19: ...application status Refer to the LabVIEW Help for information about programming this LED Ethernet LED Indicators The following table lists the Ethernet LED indicators Table 19 Ethernet LED Indicators...

Страница 20: ...he cRIO 9039 provides a chassis grounding screw Figure 6 cRIO 9039 Chassis Grounding Screw 1 1 Chassis Grounding Screw For EMC compliance you must connect the cRIO 9039 to earth ground through the cha...

Страница 21: ...k accuracy specifications CMOS Battery The cRIO 9039 contains a CMOS battery The CMOS battery is a lithium cell battery that stores the system clock information when the cRIO 9039 is powered off There...

Страница 22: ...be retracted and modules cannot be removed from a system The Module Immobilization accessory provides extra system assurance and security when shipping and installing systems and prevents accidental r...

Страница 23: ...rque of 1 3 N m 11 5 lb in 5 Install the two M3 x 0 5 flat head screws from the accessory kit in the top and bottom of the cRIO 9039 using the appropriate Torx T10 driver Tighten the screws to a maxim...

Страница 24: ...in the following image Mounting the cRIO 9039 in the reference mounting configuration ensures that your system will operate correctly across the full operating temperature range and provide optimal C...

Страница 25: ...062 in thick and extends a minimum of 101 6 mm 4 in beyond all edges of the device 3 Observe the cooling dimensions in the Mounting Requirements section 4 Allow space for cabling clearance according t...

Страница 26: ...figure The different connector types on C Series modules require different cabling clearances For a complete list of cabling clearances for C Series modules visit ni com info and enter the Info Code c...

Страница 27: ...s show the front and side dimensions of the cRIO 9039 For detailed dimensional drawings and 3D models visit ni com dimensions and search for the module number Figure 12 cRIO 9039 Front Dimensions 107...

Страница 28: ...ion NI recommends mounting the cRIO 9039 directly on a flat rigid surface using the mounting holes in the cRIO 9039 What to Use cRIO 9039 M4 screw x6 user provided which must not exceed 8 mm of insert...

Страница 29: ...the screws to a maximum torque of 1 3 N m 11 5 lb in Surface Mounting Dimensions The following figure shows the surface mounting dimensions for the cRIO 9039 Figure 14 cRIO 9039 Surface Mounting Dime...

Страница 30: ...and M4 x 10 screws Tighten the screws to a maximum torque of 1 3 N m 11 5 lb in You must use the screws provided with the NI panel mounting kit because they are the correct depth and thread for the pa...

Страница 31: ...ccuracy specifications although not guaranteed for alternate mounting configurations may be met depending on the system power and the thermal performance of the alternate mounting configuration Contac...

Страница 32: ...lip Clipping the Device on a DIN Rail Complete the following steps to clip the cRIO 9039 on a DIN rail 1 2 1 Insert one edge of the DIN rail into the deeper opening of the DIN rail clip 2 Press down f...

Страница 33: ...g kit 157268 01 in addition to a rack mounting kit Mounting the Device on a Desktop You can use the NI desktop mounting kit to mount the cRIO 9039 on a desktop What to Use cRIO 9039 Screwdriver Philli...

Страница 34: ...4 in Figure 17 cRIO 9039 Desktop Mounting Side Dimensions 132 8 mm 5 23 in 127 2 mm 5 01 in BIOS Configuration Resetting the System CMOS and BIOS Settings The cRIO 9039 BIOS configuration information...

Страница 35: ...e BIOS setup utility to change configuration settings and to enable special functions The cRIO 9039 ships with configuration settings that work for most applications but you can use the BIOS setup uti...

Страница 36: ...alues indicate the version of the controller BIOS and the date on which the BIOS was built Embedded Firmware Version This value identifies the built in hardware capabilities Processor Type Base Proces...

Страница 37: ...f power state after AC power is restored When set to Turn On the cRIO 9039 powers on when DC power is restored Power Button Off Behavior This setting specifies how the system responds to the power but...

Страница 38: ...s setting specifies the number of seconds the POST waits for a USB device or hub to power on This setting is only visible when the Device Power Up Delay is set to Manual The default value is 5 seconds...

Страница 39: ...efault settings provide the most compatible and optimal configuration Setup Prompt Timeout This setting specifies the number of seconds the system waits for a BIOS Setup menu keypress the Delete key T...

Страница 40: ...IOS settings during this session are committed to NVRAM The setup utility remains active allowing further changes Discard Changes Any changes made to BIOS settings during this session of the BIOS setu...

Страница 41: ...Worldwide Offices section of ni com niglobal to access the branch office websites which provide up to date contact information support phone numbers email addresses and current events Information is...

Страница 42: ...uipment Have surplus equipment taking up shelf space We ll give it a new home Learn more Visit us at artisantg com for more info on price quotes drivers technical specifications manuals and documentat...

Отзывы: