2 Parameters
2.2 List of parameters
SINAMICS G120 CU250S-2 Control Units
194
List Manual, 09/2017, A5E33842890
Dependency:
Refer to: p1071, r1073, r1078
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Description:
Sets the signal source for scaling the main setpoint.
Description:
Displays the effective main setpoint.
The value shown is the main setpoint after scaling.
Description:
Sets the signal source for the supplementary setpoint.
Dependency:
Refer to: p1076, r1077, r1078
Description:
Sets the signal source for scaling the supplementary setpoint.
Description:
Displays the effective supplementary setpoint. The value shown is the additional setpoint after scaling.
p1071[0...n]
CI: Main setpoint scaling / Main setp scal
Access level:
3
Calculated:
-
Data type:
U32 / FloatingPoint32
Can be changed:
T
Scaling:
PERCENT
Dyn. index:
CDS, p0170
Unit group:
-
Unit selection:
-
Func. diagram:
3001, 3030
Min Max
Factory
setting
- - 1
r1073
CO: Main setpoint effective / Main setpoint eff
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
-
Scaling:
p2000
Dyn. index:
-
Unit group:
3_1
Unit selection:
p0505
Func. diagram:
3030
Min Max
Factory
setting
- [rpm]
- [rpm]
- [rpm]
p1075[0...n]
CI: Supplementary setp / Suppl setp
Access level:
3
Calculated:
-
Data type:
U32 / FloatingPoint32
Can be changed:
T
Scaling:
p2000
Dyn. index:
CDS, p0170
Unit group:
-
Unit selection:
-
Func. diagram:
3001, 3030
Min Max
Factory
setting
- - 0
p1076[0...n]
CI: Supplementary setpoint scaling / Suppl setp scal
Access level:
3
Calculated:
-
Data type:
U32 / FloatingPoint32
Can be changed:
T
Scaling:
PERCENT
Dyn. index:
CDS, p0170
Unit group:
-
Unit selection:
-
Func. diagram:
3001, 3030
Min Max
Factory
setting
- - 1
r1077
CO: Supplementary setpoint effective / Suppl setpoint eff
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
-
Scaling:
p2000
Dyn. index:
-
Unit group:
3_1
Unit selection:
p0505
Func. diagram:
3030
Min Max
Factory
setting
- [rpm]
- [rpm]
- [rpm]
Содержание SINAMICS G120
Страница 1: ...SINAMICS SINAMICS G120 CU250S 2 Control Units List Manual 09 2017 Edition www siemens com drives ...
Страница 2: ......
Страница 726: ...2 Parameters 2 6 Quick commissioning p0010 1 SINAMICS G120 CU250S 2 Control Units 726 List Manual 09 2017 A5E33842890 ...
Страница 990: ...3 Function diagrams 3 26 Data sets SINAMICS G120 CU250S 2 Control Units 990 List Manual 09 2017 A5E33842890 ...
Страница 1242: ...A Appendix A 2 List of abbreviations SINAMICS G120 CU250S 2 Control Units 1242 List Manual 09 2017 A5E33842890 ...
Страница 1255: ......