3
F
unction
d
iag
ram
s
3.6
C
ANop
en comm
unica
tio
n
SINAMICS G120
C
U
250S-2 C
ontrol Units
79
2
List Manua
l, 09/2
017
, A5E3384289
0
F
ig.
3
-50
92
20 – CANope
n control word in
te
rco
nne
ctio
n
- 9220 -
Function diagram
8
7
6
5
4
3
2
1
fp_9220_97_68.vsd
CANopen
G120 CU250S-2 CAN
05.09.2017
V4.7.9
CANopen control word interconnection
STW.0
STW.1
STW.2
STW.3
STW.4
STW.5
STW.6
STW.8
STW.9
STW.11
STW.12
STW.13
STW.14
STW.15
STW.7
STW.10
p0848[0] = r2090.2
p0852[0] = r2090.3
p1140[0] = r2090.4
p1141[0] = r2090.5
p1142[0] = r2090.6
p2103[0] = r2090.7
<2>
<3>
-
-
pxxxx[y] = r2090.11
pxxxx[y] = r2090.12
pxxxx[y] = r2090.13
pxxxx[y] = r2090.14
pxxxx[y] = r2090.15
p0840[0] = r2090.0
p0844[0] = r2090.1
[2501.3]
[2501.3]
[2501.3]
[2501.3]
[2501.3]
[2546.1]
-
-
-
-
-
-
-
-
[2501.3]
[2501.3]
[8060]
-
-
-
-
-
-
<1>
-
Signal targets for control word CANopen
Signal
= ON (pulses can be enabled)
[Function diagram]
internal control word
[Function diagram]
signal target
0 = OFF1 (braking with RFG, then pulse suppression and ready for switching on)
1 = No coast-down activated (enable possible)
0 = Activate coast-down (immediate pulse suppression and switching on inhibited)
1 = No Quick stop activated (enable possible)
0 = Activate Quick stop (OFF3 ramp p1135, then pulse suppression and switching on inhibited)
1 = Enable operation (pulses can be enabled)
0 = Inhibit operation (suppress pulses)
1 = Enable ramp-function generator
0 = Inhibit ramp-function generator
1 = Continue ramp-function generator
0 = Freeze ramp-function generator
1 = Enable setpoint
0 = Inhibit setpoint (set the ramp-function generator input to zero)
= Acknowledge fault
1 = Stop
Reserved
Reserved
Can be freely connected
Can be freely connected
Can be freely connected
Can be freely connected
Can be freely connected
Depending on the position of the CANopen control word in p8750, the number of the binector to be connected changes.
Meaning
Sequence control
Sequence control
Sequence control
Sequence control
Not taken into account for the automatic control word interconnection (p8790).
Interconnection via p8791.
<2>
<2>
<2>
<1>
<2>
<3>
[3060], [3070]
[3060], [3070]
[3060], [3070]
[3060], [3070]
Interconnection
parameters
Содержание SINAMICS G120
Страница 1: ...SINAMICS SINAMICS G120 CU250S 2 Control Units List Manual 09 2017 Edition www siemens com drives ...
Страница 2: ......
Страница 726: ...2 Parameters 2 6 Quick commissioning p0010 1 SINAMICS G120 CU250S 2 Control Units 726 List Manual 09 2017 A5E33842890 ...
Страница 990: ...3 Function diagrams 3 26 Data sets SINAMICS G120 CU250S 2 Control Units 990 List Manual 09 2017 A5E33842890 ...
Страница 1242: ...A Appendix A 2 List of abbreviations SINAMICS G120 CU250S 2 Control Units 1242 List Manual 09 2017 A5E33842890 ...
Страница 1255: ......