2 Parameters
2.2 List of parameters
SINAMICS G120 CU250S-2 Control Units
138
List Manual, 09/2017, A5E33842890
Note:
For p0651 = 0, the operating hours counter is disabled.
When setting p0651 to 0, then p0650 is automatically set to 0.
The operating hours counter only runs with drive data set 0 and 1 (DDS).
If there is no temperature monitor, then interconnect to a fixed value.
For index 3:
When the binector input is interconnected, precharging is switched-on independent of the magnitude of the
precharging threshold.
Description:
Displays the number of inputs and outputs.
Index:
[0] = Number of digital inputs
[1] = Number of digital outputs
[2] = Number of digital input/outputs bidirectional
[3] = Number of analog inputs
[4] = Number of analog outputs
Description:
Displays the actual value at the digital inputs.
This means that the actual input signal can be checked at terminal DI x or DI/DO x prior to switching from the
simulation mode (p0795.x = 1) to terminal mode (p0795.x = 0).
Note:
If a DI/DO is parameterized as output (p0728.x = 1), then r0721.x = 0 is displayed.
DI: Digital Input
DI/DO: Bidirectional Digital Input/Output
r0720[0...4]
CU number of inputs and outputs / CU I/O count
Access level:
3
Calculated:
-
Data type:
Unsigned16
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
2119
Min Max
Factory
setting
- - -
r0721
CU digital inputs terminal actual value / CU DI term act val
Access level:
2
Calculated:
-
Data type:
Unsigned32
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
2201, 2221, 2222,
2230, 2231
Min Max
Factory
setting
- - -
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
DI 0 (T. 5)
High
Low
-
01
DI 1 (T. 6, 64)
High
Low
-
02
DI 2 (T. 7)
High
Low
-
03
DI 3 (T. 8, 65)
High
Low
-
04
DI 4 (T. 16)
High
Low
-
05
DI 5 (T. 17, 66)
High
Low
-
06
DI 6 (T. 67)
High
Low
-
11
DI 11 (T. 3, 4) AI 0
High
Low
-
12
DI 12 (T. 10, 11) AI 1
High
Low
-
16
DI 16 (T. 41)
High
Low
-
17
DI 17 (T. 42)
High
Low
-
18
DI 18 (T. 43)
High
Low
-
19
DI 19 (T. 44)
High
Low
-
24
DI/DO 24 (T. 51)
High
Low
-
25
DI/DO 25 (T. 52)
High
Low
-
26
DI/DO 26 (T. 53)
High
Low
-
27
DI/DO 27 (T. 54)
High
Low
-
Содержание SINAMICS G120
Страница 1: ...SINAMICS SINAMICS G120 CU250S 2 Control Units List Manual 09 2017 Edition www siemens com drives ...
Страница 2: ......
Страница 726: ...2 Parameters 2 6 Quick commissioning p0010 1 SINAMICS G120 CU250S 2 Control Units 726 List Manual 09 2017 A5E33842890 ...
Страница 990: ...3 Function diagrams 3 26 Data sets SINAMICS G120 CU250S 2 Control Units 990 List Manual 09 2017 A5E33842890 ...
Страница 1242: ...A Appendix A 2 List of abbreviations SINAMICS G120 CU250S 2 Control Units 1242 List Manual 09 2017 A5E33842890 ...
Страница 1255: ......