SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890
561
2 Parameters
2.2 List of parameters
Dependency:
Refer to: p9531
Note:
SLS: Safely Limited Speed
Description:
Sets the tolerance for the function "Safe motion direction" (SDI).
This motion in the monitored direction is still permissible before safety message C01716 is initiated.
Dependency:
Refer to: p9565, p9566
Refer to: C01716
Note:
SDI: Safe Direction (safe motion direction)
Description:
Sets the delay time for the function "Safe motion direction" (SDI).
After selecting the SDI function, then for a maximum of this time, motion in the monitored direction is permissible.
This time can therefore be used for braking any motion.
Dependency:
Refer to: p9564, p9566
Refer to: C01716
Note:
The set time is rounded internally to an integer multiple of the monitoring clock cycle.
SDI: Safe Direction (safe motion direction)
Description:
Sets the stop response for the function "Safe motion direction" (SDI).
This setting applies to both directions of motion.
Value:
0:
STOP A
1:
STOP B
Dependency:
Refer to: p9564, p9565
Refer to: C01716
Note:
SDI: Safe Direction (safe motion direction)
Description:
Sets the velocity tolerance limit for the "SAM" function.
SAM is deactivated once the set velocity limit has been undershot.
p9564
SI Motion SDI tolerance (processor 1) / SI Mtn SDI tol P1
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
C(95)
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
2824
Min Max
Factory
setting
0.001 [°]
360.000 [°]
12.000 [°]
p9565
SI Motion SDI delay time (processor 1) / SI Mtn SDI t P1
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
C(95)
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
2824
Min Max
Factory
setting
0.00 [ms]
600000.00 [ms]
100.00 [ms]
p9566
SI Motion SDI stop response (processor 1) / SI Mtn SDI Stop P1
Access level:
3
Calculated:
-
Data type:
Integer16
Can be changed:
C(95)
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
2824
Min Max
Factory
setting
0 1 1
p9568
SI Motion SAM velocity limit (processor 1) / SI Mtn SAM v_limP1
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
C(95)
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
0.00 [rpm]
1000.00 [rpm]
0.00 [rpm]
Содержание SINAMICS G120
Страница 1: ...SINAMICS SINAMICS G120 CU250S 2 Control Units List Manual 09 2017 Edition www siemens com drives ...
Страница 2: ......
Страница 726: ...2 Parameters 2 6 Quick commissioning p0010 1 SINAMICS G120 CU250S 2 Control Units 726 List Manual 09 2017 A5E33842890 ...
Страница 990: ...3 Function diagrams 3 26 Data sets SINAMICS G120 CU250S 2 Control Units 990 List Manual 09 2017 A5E33842890 ...
Страница 1242: ...A Appendix A 2 List of abbreviations SINAMICS G120 CU250S 2 Control Units 1242 List Manual 09 2017 A5E33842890 ...
Страница 1255: ......