Binector outputs (BO)
Product: SINAMICS G120S, Version: 4710100, Language: eng, Type: BO
r0751.0...9
BO: CU analog inputs status word / CU AI status word
r0785.0...1
BO: CU analog outputs status word / CU AO ZSW
r0807.0
BO: Master control active / PcCtrl active
r1025.0
BO: Fixed speed setpoint status / n_setp_fix status
r1979.0...12
BO: Speed_ctrl_opt status / n_opt status
r2043.0...2
BO: PROFIdrive PZD state / PD PZD state
r2090.0...15
BO: PROFIdrive PZD1 receive bit-serial / PZD1 recv bitw
r2091.0...15
BO: PROFIdrive PZD2 receive bit-serial / PZD2 recv bitw
r2092.0...15
BO: PROFIdrive PZD3 receive bit-serial / PZD3 recv bitw
r2093.0...15
BO: PROFIdrive PZD4 receive bit-serial / PZD4 recv bitw
r2094.0...15
BO: Connector-binector converter binector output / Con/bin outp
r2095.0...15
BO: Connector-binector converter binector output / Con/bin outp
r8540.0...15
BO: STW1 from IOP in the manual mode / STW1 IOP
r9935.0
BO: POWER ON delay signal / POWER ON t_delay
r20031
BO: AND 0 output Q / AND 0 output Q
r20035
BO: AND 1 output Q / AND 1 output Q
r20039
BO: AND 2 output Q / AND 2 output Q
r20043
BO: AND 3 output Q / AND 3 output Q
r20047
BO: OR 0 output Q / OR 0 output Q
r20051
BO: OR 1 output Q / OR 1 output Q
r20055
BO: OR 2 output Q / OR 2 output Q
r20059
BO: OR 3 output Q / OR 3 output Q
r20063
BO: XOR 0 output Q / XOR 0 output Q
r20067
BO: XOR 1 output Q / XOR 1 output Q
r20071
BO: XOR 2 output Q / XOR 2 output Q
r20075
BO: XOR 3 output Q / XOR 3 output Q
r20079
BO: NOT 0 inverted output / NOT 0 inv output
r20083
BO: NOT 1 inverted output / NOT 1 inv output
r20087
BO: NOT 2 inverted output / NOT 2 inv output
r20091
BO: NOT 3 inverted output / NOT 3 inv output
r20120
BO: DIV 0 divisor is zero QF / DIV 0 divisor=0 QF
r20125
BO: DIV 1 divisor is zero QF / DIV 1 divisor=0 QF
r20130
BO: AVA 0 input negative SN / AVA 0 input neg SN
r20135
BO: AVA 1 input negative SN / AVA 1 input neg SN
r20140
BO: MFP 0 output Q / MFP 0 output Q
r20145
BO: MFP 1 output Q / MFP 1 output Q
r20150
BO: PCL 0 output Q / PCL 0 output Q
r20155
BO: PCL 1 output Q / PCL 1 output Q
r20160
BO: PDE 0 output Q / PDE 0 output Q
r20165
BO: PDE 1 output Q / PDE 1 output Q
r20170
BO: PDF 0 output Q / PDF 0 output Q
r20175
BO: PDF 1 output Q / PDF 1 output Q
r20180
BO: PST 0 output Q / PST 0 output Q
r20185
BO: PST 1 output Q / PST 1 output Q
r20189
BO: RSR 0 output Q / RSR 0 output Q
r20190
BO: RSR 0 inverted output QN / RSR 0 inv outp QN
r20194
BO: RSR 1 output Q / RSR 1 output Q
r20195
BO: RSR 1 inverted output QN / RSR 1 inv outp QN
r20199
BO: DFR 0 output Q / DFR 0 output Q
r20200
BO: DFR 0 inverted output QN / DFR 0 inv outp QN
r20204
BO: DFR 1 output Q / DFR 1 output Q
r20205
BO: DFR 1 inverted output QN / DFR 1 inv outp QN
r20210
BO: BSW 0 output Q / BSW 0 output Q
Содержание SINAMICS G120
Страница 1: ...SINAMICS SINAMICS G120 CU250S 2 Control Units List Manual 09 2017 Edition www siemens com drives ...
Страница 2: ......
Страница 726: ...2 Parameters 2 6 Quick commissioning p0010 1 SINAMICS G120 CU250S 2 Control Units 726 List Manual 09 2017 A5E33842890 ...
Страница 990: ...3 Function diagrams 3 26 Data sets SINAMICS G120 CU250S 2 Control Units 990 List Manual 09 2017 A5E33842890 ...
Страница 1242: ...A Appendix A 2 List of abbreviations SINAMICS G120 CU250S 2 Control Units 1242 List Manual 09 2017 A5E33842890 ...
Страница 1255: ......