2 Parameters
2.2 List of parameters
SINAMICS G120 CU250S-2 Control Units
572
List Manual, 09/2017, A5E33842890
Description:
Displays the actual velocity values for the motion monitoring functions on processor 1.
Index:
[0] = Load-side speed actual value on processor 1
[1] = Actual SAM/SBR velocity limit on processor 1
[2] = Actual SLS velocity limit on the processor 1
Dependency:
Refer to: r9732
Notice:
For index 2:
This SLS velocity limit can, as a result of conversion into the internal monitoring format, deviate from the specified
SLS velocity limit (see r9732).
Note:
The display is updated in the safety monitoring clock cycle.
Description:
Control signals for safety-relevant motion monitoring functions integrated in the drive.
Note:
This parameter is only supplied with actual values if SI Motion functions are active. For Safety Integrated Basic
Functions (STO), the value is equal to zero.
Description:
Status signal for safety-relevant motion monitoring functions integrated in the drive on monitoring channel 1.
Notice:
For bit 07:
An internal event is displayed if a STOP A ... F is active.
The signal state behaves in an opposite way to the PROFIsafe Standard.
r9714[0...2]
CO: SI Motion diagnostics velocity (processor 1) / SI Mtn diag v P1
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
- [rpm]
- [rpm]
- [rpm]
r9720.0...13
CO/BO: SI Motion control signals integrated in the drive / SI Mtn integ STW
Access level:
3
Calculated:
-
Data type:
Unsigned32
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
2840, 2855
Min Max
Factory
setting
- - -
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
De-select STO
Yes
No
-
01
De-select SS1
Yes
No
-
04
De-select SLS
Yes
No
-
07
Acknowledgment
Signal edge active
No
-
09
Select SLS bit 0
Set
Not set
-
10
Select SLS bit 1
Set
Not set
-
12
Deselect SDI positive
Yes
No
2824
13
Deselect SDI negative
Yes
No
2824
r9722.0...15
CO/BO: SI Motion drive-integrated status signals (processor 1) / SI Mtn int stat P1
Access level:
3
Calculated:
-
Data type:
Unsigned32
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
2840, 2855
Min Max
Factory
setting
- - -
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
STO or safe pulse suppression active
Yes
No
-
01
SS1 active
Yes
No
-
04
SLS active
Yes
No
-
07
Internal event
No
Yes
-
09
Active SLS stage bit 0
Set
Not set
-
10
Active SLS stage bit 1
Set
Not set
-
12
SDI positive active
Yes
No
2824
13
SDI negative active
Yes
No
2824
15
SSM (speed below limit value)
Yes
No
2823
Содержание SINAMICS G120
Страница 1: ...SINAMICS SINAMICS G120 CU250S 2 Control Units List Manual 09 2017 Edition www siemens com drives ...
Страница 2: ......
Страница 726: ...2 Parameters 2 6 Quick commissioning p0010 1 SINAMICS G120 CU250S 2 Control Units 726 List Manual 09 2017 A5E33842890 ...
Страница 990: ...3 Function diagrams 3 26 Data sets SINAMICS G120 CU250S 2 Control Units 990 List Manual 09 2017 A5E33842890 ...
Страница 1242: ...A Appendix A 2 List of abbreviations SINAMICS G120 CU250S 2 Control Units 1242 List Manual 09 2017 A5E33842890 ...
Страница 1255: ......