2 Parameters
2.2 List of parameters
SINAMICS G120 CU250S-2 Control Units
666
List Manual, 09/2017, A5E33842890
Description:
Setting parameter for the run sequence of instance PT1 1 within the run-time group set in p20254.
Note:
The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
Description:
Sets the signal source of input quantity X and of setting value SV of instance INT 0 of the integrator.
Index:
[0] = Input X
[1] = Setting value SV
Description:
Sets the upper limit value LU of instance INT 0 of the integrator.
Description:
Sets the lower limit value LL of instance INT 0 of the integrator.
p20255
PT1 1 run sequence / PT1 1 RunSeq
CU250S_V
(FBLOCKS)
CU250S_V_CAN
(FBLOCKS)
CU250S_V_DP
(FBLOCKS)
CU250S_V_PN
(FBLOCKS)
Access level:
3
Calculated:
-
Data type:
Unsigned16
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
7262
Min Max
Factory
setting
0 32000
680
p20256[0...1]
CI: INT 0 inputs / INT 0 inputs
CU250S_V
(FBLOCKS)
CU250S_V_CAN
(FBLOCKS)
CU250S_V_DP
(FBLOCKS)
CU250S_V_PN
(FBLOCKS)
Access level:
3
Calculated:
-
Data type:
U32 / FloatingPoint32
Can be changed:
T
Scaling:
PERCENT
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
7264
Min Max
Factory
setting
- - 0
p20257
INT 0 upper limit value LU / INT 0 upper lim LU
CU250S_V
(FBLOCKS)
CU250S_V_CAN
(FBLOCKS)
CU250S_V_DP
(FBLOCKS)
CU250S_V_PN
(FBLOCKS)
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
7264
Min Max
Factory
setting
-340.28235E36 340.28235E36 0.0000
p20258
INT 0 lower limit value LL / INT 0 lower lim LL
CU250S_V
(FBLOCKS)
CU250S_V_CAN
(FBLOCKS)
CU250S_V_DP
(FBLOCKS)
CU250S_V_PN
(FBLOCKS)
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
7264
Min Max
Factory
setting
-340.28235E36 340.28235E36 0.0000
Содержание SINAMICS G120
Страница 1: ...SINAMICS SINAMICS G120 CU250S 2 Control Units List Manual 09 2017 Edition www siemens com drives ...
Страница 2: ......
Страница 726: ...2 Parameters 2 6 Quick commissioning p0010 1 SINAMICS G120 CU250S 2 Control Units 726 List Manual 09 2017 A5E33842890 ...
Страница 990: ...3 Function diagrams 3 26 Data sets SINAMICS G120 CU250S 2 Control Units 990 List Manual 09 2017 A5E33842890 ...
Страница 1242: ...A Appendix A 2 List of abbreviations SINAMICS G120 CU250S 2 Control Units 1242 List Manual 09 2017 A5E33842890 ...
Страница 1255: ......