Fault Codes
Motor Overload Setting
WARNING: Disconnect Power And Wait For LED Indicator To
Turn Off Before Touching Motor Overload Setting Switches.
1 = UP 0 = DOWN
DIP Switch Setting Motor Overload Setting (Amps)
1 2 3 4
1AB2
2AB2
1 1 1 1
2.5
4.6
1 1 1 0
2.8
5.2
1 1 0 1
3.3
5.3
1 0 1 1
3.5
5.8
0 1 1 1
3.8
6.5
0 0 0 0
4.2
6.9
Status Codes*
Green Light Codes
Constant Standby/Low Voltage
Blinking Pump Running
Red Light Codes
Constant Replace Controller
1 Blink
No Water/Loss Of Prime
2 Blinks
Tank Water-Logged
3 Blinks
Pressure Sensor Fault
4 Blinks
Pump or Motor Bound
5 Blinks
Short Circuit
6 Blinks
Ground Fault
7 Blinks
High Temperature
8 Blinks
Over Voltage (>264V)
9 Blinks
Motor Overload
*No Light - No/Very Low Voltage
Motor Overload Setting Label
Use this label to choose the correct Motor Overload Switch
Setting. This label is found under the controller access cover.
Status Code Label
Use this label to diagnose any system errors. This label is
found on the side of the controller access cover.
Application Switch Setting
WARNING: Disconnect Power And Wait For LED Indicator To Turn
Off Before Touching Application Setting Switches.
DIP Switch Setting
1 = UP 0 = DOWN
1 2 3 4
Minimum Speed (Hz)
Ramp Setting
1 1 1 1 *
10
Slow
1 1 1 0 *
10
Medium
1 1 0 1 *
10
Fast
1 0 1 1
30
Slow
0 1 1 1
30
Medium
0 0 0 0
30
Fast
*THESE SETTINGS ARE NOT TO BE USED WITH SUBMERSIBLE PUMPS.
Application
Switch
Setting
Label
Use this label
to choose
the correct
Application
Switch Setting.
This label is
found under
the controller
access cover.
Aquavar AB
2
Quick Start Up Guide
LABELS FOUND ON THE CONTROLLER ACCESS COVER:
QUICK START GUIDE
IMS-AB
2
-2