2 Parameters
2.2 List of parameters
SINAMICS G120 CU250S-2 Control Units
144
List Manual, 09/2017, A5E33842890
Description:
Setting to invert the signals at the digital outputs.
Notice:
If telegram 39x is set via p0922 in SINAMICS Integrated, the inversion of the output has no effect.
Note:
DI/DO: Bidirectional Digital Input/Output
Description:
Display and binector output for the status of the analog inputs.
Note:
AI: Analog Input
Description:
Displays the actual input voltage in V when set as voltage input.
Displays the actual input current in mA when set as current input and with the load resistor switched in.
Index:
[0] = AI0 (T. 3/4)
[1] = AI1 (T. 10/11)
Dependency:
The type of analog input AIx (voltage or current input) is set using p0756.
Refer to: p0756
Note:
AI: Analog Input
T: Terminal
p0748
CU invert digital outputs / CU DO inv
Access level:
1
Calculated:
-
Data type:
Unsigned32
Can be changed:
U, T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
-
-
0000 0000 0000 0000 0000 0000 0000
0000 bin
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
DO 0 (NO: T. 19 / NC: T. 18)
High
Low
-
01
DO 1 (NO: T. 21)
High
Low
-
02
DO 2 (NO: T. 24 / NC: T. 23)
High
Low
-
24
DI/DO 24 (T. 51)
High
Low
-
25
DI/DO 25 (T. 52)
High
Low
-
26
DI/DO 26 (T. 53)
High
Low
-
27
DI/DO 27 (T. 54)
High
Low
-
r0751.0...9
BO: CU analog inputs status word / CU AI status word
Access level:
3
Calculated:
-
Data type:
Unsigned16
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
2251
Min Max
Factory
setting
- - -
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Analog input AI0 wire breakage
Yes
No
-
01
Analog input AI1 wire breakage
Yes
No
-
08
Analog input AI0 no wire breakage
Yes
No
-
09
Analog input AI1 no wire breakage
Yes
No
-
r0752[0...1]
CO: CU analog inputs input voltage/current actual / CU AI U/I_inp act
Access level:
2
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
-
Scaling:
p0514
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
9566, 9568, 9576
Min Max
Factory
setting
- - -
Содержание SINAMICS G120
Страница 1: ...SINAMICS SINAMICS G120 CU250S 2 Control Units List Manual 09 2017 Edition www siemens com drives ...
Страница 2: ......
Страница 726: ...2 Parameters 2 6 Quick commissioning p0010 1 SINAMICS G120 CU250S 2 Control Units 726 List Manual 09 2017 A5E33842890 ...
Страница 990: ...3 Function diagrams 3 26 Data sets SINAMICS G120 CU250S 2 Control Units 990 List Manual 09 2017 A5E33842890 ...
Страница 1242: ...A Appendix A 2 List of abbreviations SINAMICS G120 CU250S 2 Control Units 1242 List Manual 09 2017 A5E33842890 ...
Страница 1255: ......