2 Parameters
2.2 List of parameters
SINAMICS G120 CU250S-2 Control Units
100
List Manual, 09/2017, A5E33842890
Description:
Sets the Sensor Module configuration.
Index:
[0] = Encoder 1
[1] = Encoder 2
[2] = Reserved
Dependency:
Refer to: p0437, p0600, p0601
Note:
A value of zero is displayed if an encoder is not present.
For bit 11:
When the property is set, the following parameters can be changed without the actual value in the encoder interface
becoming invalid (state r0481.14 = 1 "parking encoder active"):
p0314, p0315, p0430, p0431, p0441, p0442, p0443, p0444, p0445
r0458[0...2]
Sensor Module properties / SM properties
Access level:
3
Calculated:
-
Data type:
Unsigned32
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
4704
Min Max
Factory
setting
- - -
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Encoder data available
Yes
No
-
01
Motor data available
Yes
No
-
02
Temperature sensor connection available
Yes
No
-
03
Connection for PTC for motor with DRIVE-
CLiQ also available
Yes
No
-
04
Module temperature available
Yes
No
-
05
Absolute encoder p0408/p0421 no power of
2
Yes
No
-
06
Sensor Module permits parking/unparking
Yes
No
-
07
Hall sensor can be combined with actual
value inversion
Yes
No
-
08
Evaluation through several temperature
channels possible
Yes
No
-
09
Encoder fault and its associated information
available
Yes
No
-
10
Speed diagnostics in the Sensor Module
Yes
No
-
11
Configuring without park state possible
Yes
No
-
12
Extended functions available
Yes
No
-
13
Extended encoder fault handling
Yes
No
-
14
Extended singleturn/multiturn information
available
Yes
No
-
15
Evaluation function reserve
Yes
No
-
16
Pole position identification
Yes
No
-
17
Burst oversampling
Yes
No
-
18
Continuous oversampling
Yes
No
-
19
Safety position actual value sensing
Yes
No
-
20
Extended speed calculation being used
(only SMC30)
Yes
No
-
21
Zero mark tolerance
Yes
No
-
22
Rotor position adaptation
Yes
No
-
23
Commutation with zero mark can be de-
selected
Yes
No
-
24
Commutation with selected zero mark
Yes
No
-
25
Disconnection of encoder power supply on
parking supported
Yes
No
-
26
Parking with temperature evaluation
Yes
No
-
27
SSI position value extrapolation
Yes
No
-
28
Cubic correction
Yes
No
-
29
Phase correction
Yes
No
-
30
Amplitude correction
Yes
No
-
31
Offset correction
Yes
No
-
Содержание SINAMICS G120
Страница 1: ...SINAMICS SINAMICS G120 CU250S 2 Control Units List Manual 09 2017 Edition www siemens com drives ...
Страница 2: ......
Страница 726: ...2 Parameters 2 6 Quick commissioning p0010 1 SINAMICS G120 CU250S 2 Control Units 726 List Manual 09 2017 A5E33842890 ...
Страница 990: ...3 Function diagrams 3 26 Data sets SINAMICS G120 CU250S 2 Control Units 990 List Manual 09 2017 A5E33842890 ...
Страница 1242: ...A Appendix A 2 List of abbreviations SINAMICS G120 CU250S 2 Control Units 1242 List Manual 09 2017 A5E33842890 ...
Страница 1255: ......