2 Parameters
2.2 List of parameters
SINAMICS G120 CU250S-2 Control Units
434
List Manual, 09/2017, A5E33842890
Description:
Displays the position setpoint presently being processed.
Note:
A position of 0 is displayed for non position-related tasks (e.g. ENDLESS_POS, ENDLESS_NEG).
Description:
Displays the velocity setpoint presently being processed.
Description:
Displays the acceleration override presently being processed.
Note:
An override of 100% is effective in the "jogging" and "search for reference" operating modes.
Description:
Displays the deceleration override presently being processed.
Note:
An override of 100% is effective in the "jogging" and "search for reference" operating modes.
Description:
Displays the task that is presently being processed.
Value:
0:
Inactive
1:
POSITIONING
2:
FIXED STOP
3:
ENDLESS_POS
4:
ENDLESS_NEG
r2671
CO: EPOS actual position setpoint / s_set act
CU250S_V (EPOS)
CU250S_V_CAN
(EPOS)
CU250S_V_DP
(EPOS)
CU250S_V_PN
(EPOS)
Access level:
1
Calculated:
-
Data type:
Integer32
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
3610, 3616, 3620
Min Max
Factory
setting
- [LU]
- [LU]
- [LU]
r2672
CO: EPOS actual velocity setpoint / v_set act
CU250S_V (EPOS)
CU250S_V_CAN
(EPOS)
CU250S_V_DP
(EPOS)
CU250S_V_PN
(EPOS)
Access level:
1
Calculated:
-
Data type:
Integer32
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
3610, 3612, 3616,
3620
Min Max
Factory
setting
- [1000 LU/min]
- [1000 LU/min]
- [1000 LU/min]
r2673
CO: EPOS actual acceleration override / a_over act
CU250S_V (EPOS)
CU250S_V_CAN
(EPOS)
CU250S_V_DP
(EPOS)
CU250S_V_PN
(EPOS)
Access level:
1
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
3610, 3612, 3616,
3620
Min Max
Factory
setting
- [%]
- [%]
- [%]
r2674
CO: EPOS actual deceleration override / -a_over act
CU250S_V (EPOS)
CU250S_V_CAN
(EPOS)
CU250S_V_DP
(EPOS)
CU250S_V_PN
(EPOS)
Access level:
1
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
3610, 3612, 3616,
3620
Min Max
Factory
setting
- [%]
- [%]
- [%]
r2675
CO: EPOS actual task / Task act
CU250S_V (EPOS)
CU250S_V_CAN
(EPOS)
CU250S_V_DP
(EPOS)
CU250S_V_PN
(EPOS)
Access level:
1
Calculated:
-
Data type:
Integer16
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
3616
Min Max
Factory
setting
0 9 -
Содержание SINAMICS G120
Страница 1: ...SINAMICS SINAMICS G120 CU250S 2 Control Units List Manual 09 2017 Edition www siemens com drives ...
Страница 2: ......
Страница 726: ...2 Parameters 2 6 Quick commissioning p0010 1 SINAMICS G120 CU250S 2 Control Units 726 List Manual 09 2017 A5E33842890 ...
Страница 990: ...3 Function diagrams 3 26 Data sets SINAMICS G120 CU250S 2 Control Units 990 List Manual 09 2017 A5E33842890 ...
Страница 1242: ...A Appendix A 2 List of abbreviations SINAMICS G120 CU250S 2 Control Units 1242 List Manual 09 2017 A5E33842890 ...
Страница 1255: ......