2 Parameters
2.3 Command and drive data sets - overview
SINAMICS G120 CU250S-2 Control Units
700
List Manual, 09/2017, A5E33842890
p1562[0...n]
Moment of inertia estimator change time load / J_est t load
p1563[0...n]
CO: Mom. of inertia estimator load torque direction of rotation pos. / J_est M pos
p1564[0...n]
CO: Mom. of inertia estimator load torque direction of rotation neg. / J_est M neg
p1570[0...n]
CO: Flux setpoint / Flex setp
p1573[0...n]
Flux threshold value magnetizing / Flux thresh magnet
p1574[0...n]
Voltage reserve dynamic / U_reserve dyn
p1575[0...n]
Voltage target value limit / U_tgt val lim
p1580[0...n]
Efficiency optimization / Efficiency opt.
p1582[0...n]
Flux setpoint smoothing time / Flux setp T_smth
p1584[0...n]
Field weakening operation flux setpoint smoothing time / Field weak T_smth
p1586[0...n]
Field weakening characteristic scaling / Field weak scal
p1590[0...n]
Flux controller P gain / Flux controller Kp
p1594[0...n]
Field-weakening controller P gain / Field_ctrl Kp
p1595[0...n]
Field weakening controller additional setpoint / Field_ctr add_setp
p1596[0...n]
Field weakening controller integral-action time / Field_ctrl Tn
p1601[0...n]
Current injection ramp time / I_inject t_ramp
p1610[0...n]
Torque setpoint static (sensorless) / M_set static
p1611[0...n]
Additional acceleration torque (sensorless) / M_suppl_accel
p1616[0...n]
Current setpoint smoothing time / I_set T_smooth
p1654[0...n]
Curr. setpoint torque-gen. smoothing time field weakening range / Isq_s T_smth FW
p1702[0...n]
Isd current controller precontrol scaling / Isd_ctr_prectrScal
p1703[0...n]
Isq current controller precontrol scaling / Isq_ctr_prectrScal
p1715[0...n]
Current controller P gain / I_ctrl Kp
p1717[0...n]
Current controller integral-action time / I_ctrl Tn
p1726[0...n]
Quadrature arm decoupling scaling / Transv_decpl scal
p1727[0...n]
Quadrature arm decoupling at voltage limit scaling / TrnsvDecplVmaxScal
p1730[0...n]
Isd controller integral component shutdown threshold / Isd ctrl Tn shutd
p1731[0...n]
Isd controller combination current time component / Isd ctr I_combi T1
p1740[0...n]
Gain resonance damping for encoderless closed-loop control / Gain res_damp
p1744[0...n]
Motor model speed threshold stall detection / MotMod n_thr stall
p1745[0...n]
Motor model error threshold stall detection / MotMod ThreshStall
p1749[0...n]
Motor model increase changeover speed encoderless operation / Incr n_chng no enc
p1750[0...n]
Motor model configuration / MotMod config
p1752[0...n]
Motor model changeover speed operation with encoder / MotMod n_chgov enc
p1753[0...n]
Motor model changeover speed hysteresis operation with encoder / MotMod n_chgovHysE
p1755[0...n]
Motor model changeover speed encoderless operation / MotMod n_chgSnsorl
p1758[0...n]
Motor model changeover delay time closed/open-loop control / MotMod t cl_op
p1759[0...n]
Motor model changeover delay time open/closed-loop control / MotMod t op_cl
p1760[0...n]
Motor model with encoder speed adaptation Kp / MotMod wE n_ada Kp
p1761[0...n]
Motor model with encoder speed adaptation Tn / MotMod wE n_ada Tn
p1764[0...n]
Motor model without encoder speed adaptation Kp / MotMod woE n_adaKp
p1767[0...n]
Motor model without encoder speed adaptation Tn / MotMod woE n_adaTn
p1769[0...n]
Motor model changeover delay time closed-loop control / MotMod t cl_ctrl
p1774[0...n]
Motor model offset voltage compensation alpha / MotMod offs comp A
p1775[0...n]
Motor model offset voltage compensation beta / MotMod offs comp B
p1780[0...n]
Motor model adaptation configuration / MotMod adapt conf
p1784[0...n]
Motor model feedback scaling / MotMod fdbk scal
p1785[0...n]
Motor model Lh adaptation Kp / MotMod Lh Kp
p1786[0...n]
Motor model Lh adaptation integral time / MotMod Lh Tn
r1787[0...n]
Motor model Lh adaptation corrective value / MotMod Lh corr
p1795[0...n]
Motor model kT adaptation integral time / MotMod kT Tn
r1797[0...n]
Motor model kT adaptation corrective value / MotMod kT corr
p1800[0...n]
Pulse frequency setpoint / Pulse freq setp
p1802[0...n]
Modulator mode / Modulator mode
p1803[0...n]
Maximum modulation depth / Modulat depth max
Содержание SINAMICS G120
Страница 1: ...SINAMICS SINAMICS G120 CU250S 2 Control Units List Manual 09 2017 Edition www siemens com drives ...
Страница 2: ......
Страница 726: ...2 Parameters 2 6 Quick commissioning p0010 1 SINAMICS G120 CU250S 2 Control Units 726 List Manual 09 2017 A5E33842890 ...
Страница 990: ...3 Function diagrams 3 26 Data sets SINAMICS G120 CU250S 2 Control Units 990 List Manual 09 2017 A5E33842890 ...
Страница 1242: ...A Appendix A 2 List of abbreviations SINAMICS G120 CU250S 2 Control Units 1242 List Manual 09 2017 A5E33842890 ...
Страница 1255: ......