SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890
111
2 Parameters
2.2 List of parameters
Description:
Selects the trace signal to be output in r0497, r0498 and r0499 for encoder diagnostics.
Value:
0:
Inactive
1:
r0497: Mechanical revolution
10:
r0498: Raw value track A, r0499: Raw value track B
11:
r0498: Fine position X (-A/2), r0499: Fine position Y (-B/2)
12:
r0498: Fine position Phi, r0499: -
13:
r0498: Offset correction X, r0499: Offset correction Y
14:
r0498: Phase correction X, r0499: Amplitude correction Y
15:
r0498: Cubic correction X, r0499: Fine position X
16:
r0498: oversampling channel A, r0499: oversampling channel B
17:
r0498: fan-out amount, r0499: fan-out number
18:
r0498: Oversampling angle, r0499: Oversampling amount
19:
r0498: Fault counter AB, r0499: raw value track A
20:
r0498: Raw value track C, r0499: Raw value track D
21:
r0498: CD position X (-D/2), r0499: CD position Y (C/2)
22:
r0498: CD position Phi, r0499: CD pos. Phi - mech. revolution
23:
r0497: Zero mark status
24:
r0498: Raw value track R, r0499: Zero mark status
25:
r0498: Raw value track A, r0499: Raw value track R
30:
r0497: Absolute position serial
31:
r0497: Absolute position incremental
32:
r0497: Zero mark position
33:
r0497: Correction absolute position difference
40:
r0498: Raw temperature, r0499: Temperature in 0.1 °C
41:
r0498: Resistance in 0.1 Ohm, r0499: Temperature in 0.1 °C
42:
r0497: Resistance 2500 Ohm
51:
r0497: Absolute speed difference (dn/dt)
52:
r0497: Xact1 corrected quadrants
60:
Analog sensor: r0498: raw val chann. A, r0499: raw val chann. B
61:
Analog sensor: r0498: fine pos chann. A,r0499: fine pos chann. B
62:
Analog sensor: r0498: Fine pos before characteristic, r0499: -
70:
Resolver: r0498: Transformation ratio, r0499: phase
80:
Spindle: r0498: Sensor S1 (raw), r0499: Sensor S4 (raw)
81:
Spindle: r0498: Sensor S5 (raw), r0499: -
85:
Spindle: r0498: Sensor S1 (cal), r0499: Sensor S4 (cal)
86:
Spindle: r0498: Sensor S5 (cal), r0499: -
Index:
[0] = Encoder 1
[1] = Encoder 2
[2] = Reserved
Dependency:
Refer to: r0497, r0498, r0499
Notice:
The setting option depends on the following properties:
Sensor Module type, hardware version, firmware version (Sensor Module and Control Units), order number (last
digit).
Not all combinations are supported.
Note:
For p0496 = 1: 360 ° <--> 2^32
For p0496 = 10 (resolver): 2900 mV <--> 26214 dec
For p0496 = 10 (int. resolver): 1300 mV <--> 11750 dec
For p0496 = 10, 20 (sin/cos 1 Vpp, EnDat): 500 mV <--> 21299 dec
For p0496 = 11 (resolver): 2900 mV <--> 13107 dec, internal processor offset is corrected
For p0496 = 11 (int. resolver): 1300 mV <--> 5875 dec, internal processor offset is corrected
For p0496 = 11, 21 (sin/cos 1 Vpp, EnDat): 500 mV <--> 10650 dec, internal processor offset is corrected
For p0496 = 12: 180 ° fine position <--> 32768 dec
For p0496 = 13 (resolver): 2900 mV <--> 13107 dec
For p0496 = 13 (int. resolver): 1300 mV <--> 5875 dec
p0496[0...2]
Encoder diagnostic signal selection / Enc diag select
Access level:
4
Calculated:
-
Data type:
Integer16
Can be changed:
U, T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
0 86
0
Содержание SINAMICS G120
Страница 1: ...SINAMICS SINAMICS G120 CU250S 2 Control Units List Manual 09 2017 Edition www siemens com drives ...
Страница 2: ......
Страница 726: ...2 Parameters 2 6 Quick commissioning p0010 1 SINAMICS G120 CU250S 2 Control Units 726 List Manual 09 2017 A5E33842890 ...
Страница 990: ...3 Function diagrams 3 26 Data sets SINAMICS G120 CU250S 2 Control Units 990 List Manual 09 2017 A5E33842890 ...
Страница 1242: ...A Appendix A 2 List of abbreviations SINAMICS G120 CU250S 2 Control Units 1242 List Manual 09 2017 A5E33842890 ...
Страница 1255: ......