SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890
83
2 Parameters
2.2 List of parameters
Notice:
An encoder type with p0400 < 9999 defines an encoder for which there is an encoder parameter list.
When selecting a catalog encoder (p0400 < 9999) the parameters from the encoder parameter list cannot be
changed (write protection). To remove write protection, the encoder type should be set to a third-party encoder
(p0400 = 9999).
If the encoder interface p0468[x] is reconfigured, the encoder configuration is reset p0400[x] = 0.
Note:
The connected encoder can be identified by setting p0400 to 10000 or 10100. This assumes that the encoder
supports this method, which is possible in the following cases: Motor with DRIVE-CLiQ, encoder with EnDat
interface, DRIVE-CLiQ encoder, encoder with SSI interface (only 10100).
The encoder data (e.g. pulse number p0408) can only be changed when p0400 = 9999.
When using an encoder with track A/B and zero pulse, as standard, fine synchronization is not set using a zero mark.
If, for a synchronous motor, fine synchronization is to be realized using a zero mark, then the following must be
executed:
- set p0400 to 9999
- set p0404.15 to 1
Prerequisite:
Coarse synchronization must be selected (e.g. pole position identification) and the zero pulse of the encoder must be
either mechanically or electronically (p0431) adjusted to the pole position.
For p0400 = 10000 the following applies:
If an identification is not possible, then p0400 is set to 0.
For p0400 = 10100 the following applies:
If an identification is not possible, p0400 remains set to 10100 until it becomes possible.
Description:
Selects the gearbox type to pre-set the inversion and the gearbox factor.
Measuring gear factor = motor or load revolutions / encoder revolutions.
Value:
1:
Gearbox 1:1 not inverted
2:
Gearbox 2:7 inverted
3:
Gearbox 4:17 inverted
4:
Gearbox 2:10 inverted
9999: Gearbox user-defined
10000: Identify gearbox
10100: Identify gearbox
Dependency:
Refer to: p0410, p0432, p0433
Note:
For p0402 = 1:
Automatic setting of p0410 = 0000 bin, p0432 = 1, p0433 = 1.
For p0402 = 2:
Automatic setting of p0410 = 0011 bin, p0432 = 7, p0433 = 2.
For p0402 = 3:
Automatic setting of p0410 = 0011 bin, p0432 = 17, p0433 = 4.
For p0402 = 4:
Automatic setting of p0410 = 0011 bin, p0432 = 10, p0433 = 2.
For p0402 = 9999:
No automatic setting of p0410, p0432, p0433. The parameters should be manually set.
For p0402 = 10000:
It is only possible to identify the gearbox type for a motor with DRIVE-CLiQ. Parameters p0410, p0432 and p0433 are
set corresponding to the identified gearbox. If an identification is not possible, then p0402 is set to 9999.
p0402[0...n]
Gearbox type selection / Gearbox type sel
Access level:
1
Calculated:
-
Data type:
Integer16
Can be changed:
C(1, 4)
Scaling:
-
Dyn. index:
EDS, p0140
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
1 10100
9999
Содержание SINAMICS G120
Страница 1: ...SINAMICS SINAMICS G120 CU250S 2 Control Units List Manual 09 2017 Edition www siemens com drives ...
Страница 2: ......
Страница 726: ...2 Parameters 2 6 Quick commissioning p0010 1 SINAMICS G120 CU250S 2 Control Units 726 List Manual 09 2017 A5E33842890 ...
Страница 990: ...3 Function diagrams 3 26 Data sets SINAMICS G120 CU250S 2 Control Units 990 List Manual 09 2017 A5E33842890 ...
Страница 1242: ...A Appendix A 2 List of abbreviations SINAMICS G120 CU250S 2 Control Units 1242 List Manual 09 2017 A5E33842890 ...
Страница 1255: ......