Data sheet

Description

The actuators are used together with 

automatically balanced combination valve type 

AB-QM for DN 10-32.

The actuator can be used with fan coil units, 

induction units, small reheaters, recoolers and 

zone applications in which hot/cold water is the 

controlled medium. 

Main data:

•  Gap detection at stem up position

•  Modulating control

•  Force switch-off at stem down position 

prevents overload of actuator and valve

•  No tools required for mounting

•  Maintenance-free lifetime 

•  Low-noise operation

•  Self-positioning process

•  Halogen free cables

Ordering

Type

Supply voltage

Speed

Cable length

Code No,

(V)

(s/mm)

(m)

Single Pack

Industry Pack

AME 110 NL

24 AC

24

1,5 

082H8057

082H8067

5,0 

082H8081

082H8077

10 

082H8098

082H8087

AME 120 NL

12

1,5 

082H8059

/

5,0 

/

082H8079

10 

/

082H8089

Note: 

 

Actuators with 5 m and 10 m cable length are produced on request. Please note this increases lead time.

Spare parts

Type

Length

Code No.

(m)

Cable (24 V)

5

082H8052

10

082H8054

Содержание AME 110 NL

Страница 1: ...dulating control Force switch off at stem down position prevents overload of actuator and valve No tools required for mounting Maintenance free lifetime Low noise operation Self positioning process Ha...

Страница 2: ...w18y2013 Installation Mechanical The actuator should be mounted with the valve stem in either horizontal position or pointing upwards The actuator is fixed to the valve body by means of a mounting rin...

Страница 3: ...urely on the valve body 2 Wire the actuator according to the wiring diagram 3 The direction of the stem movement can be observed on the position indicator Installation procedure Wiring Commissioning T...

Страница 4: ...al range 0 2 5 6 V or 0 4 0 12 mA or 5 6 10 V or 10 12 20 mA SW 5 0 5 5 10 V Input signal range in sequential mode If set to OFF position the actuator is working in the sequential range 0 2 5 6 V or 0...

Страница 5: ...s that the gear wheel has jumped into normal position If manual override has been used the Y signal will not be correct until the actuator has reached its end position If this is not acceptable reset...

Страница 6: ...6 VD KH C6 02 Danfoss 01 2014 SMT SI Data sheet Actuators for modulating control AME 110 NL AME 120 NL...

Страница 7: ...7 VD KH C6 02 Danfoss 01 2014 SMT SI Data sheet Actuators for modulating control AME 110 NL AME 120 NL...

Страница 8: ...8 VD KH C6 02 Produced by Danfoss A S 01 2014 Data sheet Actuators for modulating control AME 110 NL AME 120 NL...

Отзывы: