2 Parameters
2.2 List of parameters
SINAMICS G120 CU250S-2 Control Units
470
List Manual, 09/2017, A5E33842890
Description:
Trace functionality for OEM encoder manufacturers.
Index:
[0] = Encoder 1
[1] = Encoder 2
[2] = Encoder 3
Description:
Sets the component number (p0141) of the encoder whose functional reserve is to be displayed (r4651).
Dependency:
Refer to: r4651
Description:
Displays the functional reserve of the encoder selected via p4650.
0 ... 25 %:
The function limit has been reached. A service is recommended.
26 ... 100 %:
The encoder is working in the specified range.
Index:
[0] = Function reserve 1
[1] = Function reserve 2
[2] = Function reserve 3
[3] = Function reserve 4
Dependency:
Refer to: p4650
Note:
Value = 999 means:
- the component specified in p4650 is not connected
- the encoder does not support the display of the functional reserve
Description:
Sets the mode to reset the actual value in XIST_ERW (CO: r4653).
Value:
0:
Inactive
1:
Reset with zero mark
2:
Reset with BICO
3:
Reset with selected zero mark
Index:
[0] = Encoder 1
[1] = Encoder 2
[2] = Reserved
p4641[0...2]
OEM encoder diagnostic signal selection / OEM enc diag sel
Access level:
3
Calculated:
-
Data type:
Unsigned16
Can be changed:
U, T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
0 65535
0
p4650
Encoder functional reserve component number / Enc fct_res num
Access level:
3
Calculated:
-
Data type:
Unsigned16
Can be changed:
U, T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
0 399
0
r4651[0...3]
Encoder functional reserve / Enc fct_reserve
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
- [%]
- [%]
- [%]
p4652[0...2]
XIST1_ERW reset mode / XIST1_ERW res mode
Access level:
3
Calculated:
-
Data type:
Integer16
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
4750
Min Max
Factory
setting
0 3 0
Содержание SINAMICS G120
Страница 1: ...SINAMICS SINAMICS G120 CU250S 2 Control Units List Manual 09 2017 Edition www siemens com drives ...
Страница 2: ......
Страница 726: ...2 Parameters 2 6 Quick commissioning p0010 1 SINAMICS G120 CU250S 2 Control Units 726 List Manual 09 2017 A5E33842890 ...
Страница 990: ...3 Function diagrams 3 26 Data sets SINAMICS G120 CU250S 2 Control Units 990 List Manual 09 2017 A5E33842890 ...
Страница 1242: ...A Appendix A 2 List of abbreviations SINAMICS G120 CU250S 2 Control Units 1242 List Manual 09 2017 A5E33842890 ...
Страница 1255: ......