2 Parameters
2.2 List of parameters
SINAMICS G120 CU250S-2 Control Units
552
List Manual, 09/2017, A5E33842890
Description:
Displays the number of modified parameters and those that have still not be saved for this drive object.
Dependency:
Refer to: p0971
Notice:
Inherent to the system, the list of the parameters to be backed up is empty after the following actions:
- Download
- Warm restart
- Factory setting
In these cases, a new parameter backup must be initiated, which is then the starting point for the list of modified
parameters.
Note:
The modified parameters that still need to be saved are internally listed in r9410 ... r9419.
Description:
Displays the parameters whose parameter would have to be changed during a units changeover.
Dependency:
Refer to: F07088
Description:
Displays the set valid macro.
Note:
A value of 0 is displayed if a parameter set by a macro is changed.
Description:
Sets the signal source (BO/CO parameter, BICO coded) to search in the signal sinks.
The signal source to be searched for is set in p9484 (BICO-coded) and the search result is specified using the
number (r9485) and the first index (r9486).
Dependency:
Refer to: r9485, r9486
r9409
Number of parameters to be saved / Qty par to save
Access level:
4
Calculated:
-
Data type:
Unsigned16
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
- - -
r9451[0...29]
Units changeover adapted parameters / Unit_chngov par
Access level:
4
Calculated:
-
Data type:
Unsigned32
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
- - -
r9463
Actual macro / Actual macro
Access level:
3
Calculated:
-
Data type:
Unsigned32
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
0 999999
-
p9484
BICO interconnections search signal source / BICO S_src srch
Access level:
3
Calculated:
-
Data type:
Unsigned32
Can be changed:
U, T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
0 4294967295
0
Содержание SINAMICS G120
Страница 1: ...SINAMICS SINAMICS G120 CU250S 2 Control Units List Manual 09 2017 Edition www siemens com drives ...
Страница 2: ......
Страница 726: ...2 Parameters 2 6 Quick commissioning p0010 1 SINAMICS G120 CU250S 2 Control Units 726 List Manual 09 2017 A5E33842890 ...
Страница 990: ...3 Function diagrams 3 26 Data sets SINAMICS G120 CU250S 2 Control Units 990 List Manual 09 2017 A5E33842890 ...
Страница 1242: ...A Appendix A 2 List of abbreviations SINAMICS G120 CU250S 2 Control Units 1242 List Manual 09 2017 A5E33842890 ...
Страница 1255: ......