2 Parameters
2.2 List of parameters
SINAMICS G120 CU250S-2 Control Units
472
List Manual, 09/2017, A5E33842890
Description:
Sets the filter bandwidth for Sensor Module SMx10 (resolver) and SMx20 (sin/cos).
The value set on the Sensor Module is displayed in r4661.
Currently, the Sensor Module hardware only supports the following values:
- 0: The Sensor Module's default setting is used.
- 50 kHz
- 170 kHz
- 500 kHz
- Unlimited: Only the bandwidth of the operational amplifier is effective.
Index:
[0] = Encoder 1
[1] = Encoder 2
[2] = Reserved
Dependency:
Refer to: r4661
Note:
A value of zero is displayed if an encoder is not present.
Description:
Displays the effective filter bandwidth for Sensor Module SMx10 (resolver) and SMx20 (sin/cos).
The bandwidth of the filter is set using p4660.
Index:
[0] = Encoder 1
[1] = Encoder 2
[2] = Reserved
Dependency:
Refer to: p4660
Note:
A value of zero is displayed if an encoder is not present.
Description:
Sets the characteristic type.
For non-linear sensors, the interrelationship between the signal voltage and the position can be defined using a third
degree polynomial.
Value:
0:
Characteristic inactive
1:
Characteristic polynomial third degree
Dependency:
Refer to: p4663, p4664, p4665, p4666
Note:
If value = 1:
A third degree polynomial is defined as follows:
F(x) = K3 * x^3 + K2 * x^2 + K1 * x + K0
Coefficients K0 ... K3 should be defined and entered into p4663 ... p4666.
The sensor range is emulated to x = -0.5 ... +0.5.
p4660[0...2]
Sensor Module filter bandwidth / SM Filt_bandw
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
C(4)
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
0.00 [kHz]
20000.00 [kHz]
0.00 [kHz]
r4661[0...2]
Sensor Module filter bandwidth display / SM Filt_bandw disp
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
- [kHz]
- [kHz]
- [kHz]
p4662[0...n]
Encoder characteristic type / Enc char_type
Access level:
4
Calculated:
-
Data type:
Integer16
Can be changed:
C(4)
Scaling:
-
Dyn. index:
EDS, p0140
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
0 1 0
Содержание SINAMICS G120
Страница 1: ...SINAMICS SINAMICS G120 CU250S 2 Control Units List Manual 09 2017 Edition www siemens com drives ...
Страница 2: ......
Страница 726: ...2 Parameters 2 6 Quick commissioning p0010 1 SINAMICS G120 CU250S 2 Control Units 726 List Manual 09 2017 A5E33842890 ...
Страница 990: ...3 Function diagrams 3 26 Data sets SINAMICS G120 CU250S 2 Control Units 990 List Manual 09 2017 A5E33842890 ...
Страница 1242: ...A Appendix A 2 List of abbreviations SINAMICS G120 CU250S 2 Control Units 1242 List Manual 09 2017 A5E33842890 ...
Страница 1255: ......