EN
ALARM CONTROL UNIT
CPX200NB
User manual
Version of the manual:
v1.6
Date of issue:
2016.01.08
Firmware version:
2.3.7
GPRS transmitter configurator version:
1.3.54.10
OSM server version:
1.3.53.3
Страница 1: ...EN ALARM CONTROL UNIT CPX200NB User manual Version of the manual v1 6 Date of issue 2016 01 08 Firmware version 2 3 7 GPRS transmitter configurator version 1 3 54 10 OSM server version 1 3 53 3...
Страница 2: ...not be deemed to be providing any warranties either express or implicit including but not limited to any implied warranties of merchantability or fitness for a particular purpose unless it is required...
Страница 3: ...SYSTEM 12 5 2 ALARM DISPLAY 12 5 3 ALARM MUTE 12 6 PARTITION HANDLING 13 6 1 ARMING DISARMING WITH SELECTING PARTITIONS 13 6 2 QUICK ARMING DISARMING PARTITIONS 13 7 USER FUNCTIONS 15 7 1 ALARMS MEMO...
Страница 4: ...sized facilities The central unit is equipped with 3 outputs and 7 wired zones with the possibility to be divided into 2 partitions Dedicated KP16 LED keypad was designed in a modern discreet style P...
Страница 5: ...100mA PARTITIONS 2 partitions with the possibility to assign any number of zones to each of them KEYBOARD cooperation with LED keyboard KP16 ability to connect up to three keypads TRANSMISSION Transmi...
Страница 6: ...arged battery established connection with server connected keypad no sensors connected 120mA 1100mA 18VAC Average current consumption lack of external supply without keypad with keypad fully charged b...
Страница 7: ...ION Power supply voltage 10 13 8 VDC Power consumption typ 20 mA max 80 mA Keypad weight 70 g Size of casing 99 x 82 x 19 mm Keypad type LED 16 status LEDs 4 mode LEDs ALARM ARMED SYSTEM PROG Button l...
Страница 8: ...ellow Flashing light means that in the control unit s memory there are faults that has already ceased there was power loss but it has already restored Constant light there is a fault in the system tha...
Страница 9: ...t slightly in indicated hole and perform slight lever movement toward the rear side of the casing 11 Anti Sabotage Switch After the keypad is assembled the switch contact is closed Unauthorized disass...
Страница 10: ...an automatically arm in the away mode if proper conditions were met 4 2 1 Stay mode Arming the partition in stay mode is possibile only if it has perimeter zones assigned to it Partition will arm in t...
Страница 11: ...the keypad until the system gets fully armed If the chirps are activated the arming will be confirmed by one chirp of siren 4 3 ARMING THE SYSTEM WITH FAULT If during the arming any faults are presen...
Страница 12: ...different way by changing the partition state See item 6 PARTITION HANDLING 4 When system is disarmed alarm will be muted deactivated Note Incorrect code will be indicated with a long constant sound...
Страница 13: ...cancel the entered changes press 4 If partition arming in the away auto mode was selected the keypad will indicate counting the time for leaving the facility Leave the facility before the time for lea...
Страница 14: ...ing expires After it is armed the ARMED LED will be constantly on 3 If the partition arming in the stay mode was selected system will arm immidiately ARMED LED will turn on 4 If partition disarming is...
Страница 15: ...lines 1 to 7 If no diodes are on and the ALARM led is blinking then there alarms that were triggered by the source other than input lines Other alarms history can be accessed by selecting following co...
Страница 16: ...ion about sabotage of zones press button 1 Sabotage of zone 1 2 Sabotage of zone 2 7 Sabotage of zone 7 To return to the main fault menu press 2 Fault of outputs 1 3 To display more detailed informati...
Страница 17: ...with quickly flashing LED marked with the number of the blocked zone Zone blocking 1 Enter the number of the function and confirm with Enter the user code and press 3 tone beep will confirm the corre...
Страница 18: ...o exit without saving changes 8 Successful adding a new user will be confirmed with 3 beeps otherwise a constant sound will be emitted 7 5 USER DELETE You can delete a user here Codes can be deleted b...
Страница 19: ...nistrator code hh mm where Administrator code Administrator code hh Hours mm Minutes In any moment you can press to exit without saving changes 7 8 PROGRAMMING DATE You can change system date here Dat...
Страница 20: ...an alarm but not reporting the event to the monitoring station Thus the siren or other signalling devices can be checked Repeated pressing the key disables the output To exit the testing function pre...
Страница 21: ...e device in order to configure it or poll its status For SMS to be accepted the phone number from which the text is being send has to be enlisted on the allowed numbers list CPX200NB can store up to 1...
Страница 22: ...MED ERROR command rejected by the system Setting the name of partition Command syntax XXXX SETNAME PARTITION NR VALUE Command description Setting the name of the partition XXXX user code NR number of...
Страница 23: ...ion GETNAME PARTITION NR VALUE partition name GETNAME ERROR command rejected by the system Setting the phone number Command syntax XXXX SETTELNUM ID NUMBER Command description Setting the phone number...
Страница 24: ...message description GETTELNUM ID NUMBER information about phone number GETTELNUM ERROR command rejected by the system Setting the content of text message Command syntax XXXX SETMESSAGE ID MESSAGE Comm...
Страница 25: ...ing the content of text message under the pointed index XXXX user code ID index of text possible values 1 to 32 Example 1234 GETMESSAGE 30 Feedback message GETMESSAGE ID MESSAGE or GETMESSAGE ERROR Fe...
Страница 26: ...Each digit counting from the left represents an index of the phone number first digit for the first phone number second digit for the second number and so on 0 message will not be send to this number...
Страница 27: ...mber assigned to the specified event XXXX user code EVENT a short name of the event possible event names are listed at the end of this chapter Example 1234 GETUSERSMS ARM1 Feedback message GETUSERSMS...
Страница 28: ...INPUT1 OFF to INPUT7 OFF Violation of zones 1 7 ended INPUT1 TAMPER to INPUT7 TAMPER Sabotage of zones 1 7 INPUT1 TAMPEREND to INPUT7 TAMPEREND Sabotage of zones 1 7 ended INPUT1 LOCK to INPUT7 LOCK B...
Страница 29: ...to KEYPAD3 TAMPER Sabotage of keypad 1 3 KEYPAD1 TAMPEREND to KEYPAD3 TAMPEREND Sabotage of keypad 1 3 ended KEYPAD FIRE BEGIN Fire alarm started KEYPAD HELP BEGIN Help alarm started KEYPAD SILENTALAR...
Страница 30: ...n entered arming requires authorization prior to arming the control panel checks circumstances that may prevent arming the codes in the system must be at least 5 characters after entering an invalid c...