2 Parameters
2.2 List of parameters
SINAMICS G120 CU250S-2 Control Units
412
List Manual, 09/2017, A5E33842890
Description:
Sets the signal source to start the "search for reference" or "flying referencing".
BI: p2595 = 0/1 signal
Referencing is started.
BI: p2595 = 1/0 signal
Referencing is interrupted.
Dependency:
Refer to: p2597, p2598, p2599, r2684
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note:
Search for reference (BI: p2597 = 0 signal):
The reference point approach can only be activated (0/1 edge) after traversing motion that is being processed has
been completed.
With the start, where relevant, the state signal "reference point set" (r2684.11) is reset.
Flying referencing (BI: p2597 = 1 signal):
With the start, the state signal "reference point set" (r2684.11) is not reset.
Description:
Sets the signal source for the "set reference point".
Dependency:
Refer to: p2598, p2599, r2684
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note:
Reference point setting is effective in the following operating states:
- in the basic state.
- for FIXED STOP with progress condition END (corresponds to the initial state).
- for traversing block interrupted via BI: p2640 = 0 signal (intermediate stop).
- for EPOS not enabled (BI: p2656 = 0 signal) and position actual value valid (BI: p2658 = 1 signal).
Description:
Sets the signal source to select referencing type.
1 signal: Flying referencing
0 signal: Search for reference
Dependency:
Refer to: p2595
Note:
Referencing is activated as follows:
- Select the referencing type (BI: p2597)
- Start referencing (BI: p2595 = 0/1 signal)
p2595
BI: EPOS referencing start / Ref start
CU250S_V (EPOS)
CU250S_V_CAN
(EPOS)
CU250S_V_DP
(EPOS)
CU250S_V_PN
(EPOS)
Access level:
1
Calculated:
-
Data type:
U32 / Binary
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
3612, 3625, 3614
Min Max
Factory
setting
- - 0
p2596
BI: EPOS set reference point / Set ref_pt
CU250S_V (EPOS)
CU250S_V_CAN
(EPOS)
CU250S_V_DP
(EPOS)
CU250S_V_PN
(EPOS)
Access level:
1
Calculated:
-
Data type:
U32 / Binary
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
3612
Min Max
Factory
setting
- - 0
p2597
BI: EPOS referencing type selection / Ref_typ select
CU250S_V (EPOS)
CU250S_V_CAN
(EPOS)
CU250S_V_DP
(EPOS)
CU250S_V_PN
(EPOS)
Access level:
1
Calculated:
-
Data type:
U32 / Binary
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
3612, 3614, 3625
Min Max
Factory
setting
- - 0
Содержание SINAMICS G120
Страница 1: ...SINAMICS SINAMICS G120 CU250S 2 Control Units List Manual 09 2017 Edition www siemens com drives ...
Страница 2: ......
Страница 726: ...2 Parameters 2 6 Quick commissioning p0010 1 SINAMICS G120 CU250S 2 Control Units 726 List Manual 09 2017 A5E33842890 ...
Страница 990: ...3 Function diagrams 3 26 Data sets SINAMICS G120 CU250S 2 Control Units 990 List Manual 09 2017 A5E33842890 ...
Страница 1242: ...A Appendix A 2 List of abbreviations SINAMICS G120 CU250S 2 Control Units 1242 List Manual 09 2017 A5E33842890 ...
Страница 1255: ......