Modules for 230V Fan Range

 

Installation and Operating Guide

 

PCM  –

  72573602

 

TM  –

  72612601

 

DTM  –

  72675702

 

HTM  –

  72687103

 

PRTM  –

  72687104

 

PRHTM  –

  72687102

 

2SHM  –

  72675703

 

iCON 230V Fan Range Available Modules 

 

Page 2 of 8

 

Page 3 of 8

 

Electrical installation

 

Page 4 of 8

 

Mechanical installation

 

Airflow iCON fans can be controlled by optional control mod-

ules. For the 230V range you can choose between seven 

modules. 

 

* For blister pack add 

B

” 

at the end of part number. 

 

 

** 

Not for kitchen applications with iCON 15! 

Approved Document Part F required 

continuous extract rates: 6 l/s for WC, 8 l/s for bathroom / utility room and 13 l/s for 

kitchen.

 

 

SAFETY FIRST: ALWAYS ISOLATE THE FAN 

UNIT FROM THE POWER SUPPLY BEFORE  

DOING ANY WORK ON THE FAN/MODULE.

 

Part no*

 

Model

 

Description

 

W

iri

n

g

 

D

ia

g

ra

m

 

72573602

 

PCM

 

Pull cord

 (Manual on/off) 

 

A

 

72612601

 

TM

 

Timer

 (Run on timer 1 

-

 30 min) 

 

B

 

72675702

 

DTM

 

Delayed timer

 (2 min delay, Run on timer 2 

-

 45 min, Pull cord) 

 

B

 

72687103

 

HTM

 

Humidity timer

 (40 

-

 90% RH, Run on timer 2 

-

 45 min, Pull 

cord)

 

A, B

 

72687104

 

PRTM

 

PIR timer

 (Motion sensor, Run on timer 2 

-

 45min)

 

A, B

 

72687102

 

PRHTM

 

PIR humidity timer

 (Motion sensor, 40 

-

 90% RH, Run on timer 

-

 45 min)

 

A, B

 

72675703

 

2SHM**

 

2 speed humidity

 (Low speed 8 or 13 l/s, Boost at 40 

-

 90% 

RH, Pull Cord)

 

A, B

 

All electrical installation work to be carried out by an ap-
proved competent person in compliance with U.K. Building 
Regulations and to the latest IET standards, or the appropri-
ate regulations in the country of installation. (for fan installa-
tion see the iCON 230V Fan Range Installation and Operat-
ing Guide). 

 

Diagram  A

 

-

  module  wiring  with  no  external  switching 

(module functionality / pull cord activation only): 

 

 

Diagram  B

 

-

  module  wiring  with  external  switching  (live 

trigger connection used):

 

To  install  the  module  in  an  iCON  fan  follow  the  instructions 

below. See page 5 

-

 8 for instructional drawings.  

 

1.

 

Remove the iCON fan front cover (see page 5). 

 

2.

 

Lift the fan electrical terminal away from its mounting pillars 

and position on the module connector pins. Tighten the two 

screws  with  a  suitable  screwdriver.  Ensure  the  leads  are 

under the module retaining cable clamp. 

 

3.

 

Fit the module at a slight angle into the fan housing, ensur-

ing that the locating slot is fully engaged in to the locating 

block on the fan. 

 

4.

 

Push the module against housing, ensuring the module clip 

holds it in place (clicks at the cable clamp). With iCON 15 

& 30 the terminal will reposition back over mounting pillars. 

 

Modules with pull cord: 

Ensure that the pull cord is properly 

located within the cord slot at the bottom of the fan.

 

Modules  with  PIR  control: 

Remove the oval logo cap fitted 

at  the  bottom  of  the  front  cover  of  the  fan.  Replace  it  with 

translucent  lens  supplied  with  the  PIR  module.  Note:  The 

lens must be replaced in order for the PIR module to function 

properly. Ensure the orientation of the lens is correct (i.e. the 

lens should be flush with the surface). 

 

Connecting mains cable into the module

 

Connect the cable to the 3

-

way supply connector block (see 

wiring diagrams on page 3) ensuring that the supplied cable 

clamp is fitted. Refit the front cover.

 

Note:

 When using DTM module on initial connection the fan 

will  start  immediately  and  continue  running  for  the  duration 

set on the timer function of the module.

 

Certificate No. FM 00152

 

BS EN ISO 9001:2015

 

Certificate No. EMS 569454

 

BS EN ISO 14001:2015

 