2 Parameters
2.2 List of parameters
SINAMICS G120 CU250S-2 Control Units
524
List Manual, 09/2017, A5E33842890
Index 8 corresponds to the CANopen object 5818 hex
Index 9 corresponds to the CANopen object 5819 hex
Index 10 corresponds to the CANopen object 581A hex
Index 11 corresponds to the CANopen object 581B hex
Index 12 corresponds to the CANopen object 581C hex
Index 13 corresponds to the CANopen object 581D hex
Index 14 corresponds to the CANopen object 581E hex
Index 15 corresponds to the CANopen object 581F hex
Description:
Access to free PZD receive objects 32 bit using the SDO transfer.
An index can only be used, if the corresponding object has not been mapped in a PDO.
Index:
[0] = PZD object 0
[1] = PZD object 1
[2] = PZD object 2
[3] = PZD object 3
[4] = PZD object 4
[5] = PZD object 5
[6] = PZD object 6
[7] = PZD object 7
Note:
Index 0 corresponds to the CANopen object 5820 hex
Index 1 corresponds to the CANopen object 5821 hex
Index 2 corresponds to the CANopen object 5822 hex
Index 3 corresponds to the CANopen object 5823 hex
Index 4 corresponds to the CANopen object 5824 hex
Index 5 corresponds to the CANopen object 5825 hex
Index 6 corresponds to the CANopen object 5826 hex
Index 7 corresponds to the CANopen object 5827 hex
Description:
Sets the signal source for free PZD send objects 32 bit for SDO transfer.
An index can only be used, if the corresponding object has not been mapped in a PDO.
Index:
[0] = PZD object 0
[1] = PZD object 1
[2] = PZD object 2
[3] = PZD object 3
[4] = PZD object 4
[5] = PZD object 5
[6] = PZD object 6
[7] = PZD object 7
Note:
Index 0 corresponds to the CANopen object 5830 hex
Index 1 corresponds to the CANopen object 5831 hex
Index 2 corresponds to the CANopen object 5832 hex
Index 3 corresponds to the CANopen object 5833 hex
Index 4 corresponds to the CANopen object 5834 hex
Index 5 corresponds to the CANopen object 5835 hex
r8747[0...7]
CO: CAN free PZD receive objects 32 bit / Free PZD recv 32
CU250S_V_CAN
Access level:
3
Calculated:
-
Data type:
Integer32
Can be changed:
-
Scaling:
4000H
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
- - -
p8748[0...7]
CI: CAN free PZD send objects 32 bit / Free PZD send 32
CU250S_V_CAN
Access level:
3
Calculated:
-
Data type:
U32 / Integer32
Can be changed:
U, T
Scaling:
4000H
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
- - 0
Содержание SINAMICS G120
Страница 1: ...SINAMICS SINAMICS G120 CU250S 2 Control Units List Manual 09 2017 Edition www siemens com drives ...
Страница 2: ......
Страница 726: ...2 Parameters 2 6 Quick commissioning p0010 1 SINAMICS G120 CU250S 2 Control Units 726 List Manual 09 2017 A5E33842890 ...
Страница 990: ...3 Function diagrams 3 26 Data sets SINAMICS G120 CU250S 2 Control Units 990 List Manual 09 2017 A5E33842890 ...
Страница 1242: ...A Appendix A 2 List of abbreviations SINAMICS G120 CU250S 2 Control Units 1242 List Manual 09 2017 A5E33842890 ...
Страница 1255: ......