2 Parameters
2.2 List of parameters
SINAMICS G120 CU250S-2 Control Units
554
List Manual, 09/2017, A5E33842890
Value:
0:
Inactive
1:
Restore the interconnections from the list
2:
Delete the interconnections from the list
Dependency:
Refer to: p9495, p9497, p9498, p9499
Refer to: A01318, A01507
Note:
The BI/CI parameters involved are listed in p9498[0...29] (signal sink).
The associated BO/CO parameters are listed in p9499[0...29] (signal source).
After p9496 = 1, 2 the following applies:
- p9497 = 0
- p9496 = 0
Description:
Displays the number of saved BICO interconnections to drive objects that are either not capable of operation or have
been deactivated.
BO/CO parameters are on the drive object that is either not capable of operation or has been deactivated (signal
source).
Dependency:
Refer to: p9495, p9496, p9498, p9499
Refer to: A01318, A01507
Description:
Displays the saved BI/CI parameters (signal sink), whose source is located on drive objects that are either not
capable of operation or have been deactivated.
Dependency:
Refer to: p9495, p9496, p9497, p9499
Refer to: A01318, A01507
Note:
A BICO interconnection (signal sink, signal source) is displayed in the same index of p9498 and p9499.
Description:
Displays the saved BO/CO parameters (signal source), which are located on drive objects that are either not capable
of operation or have been deactivated.
Dependency:
Refer to: p9495, p9496, p9497, p9498
Refer to: A01318, A01507
Note:
A BICO interconnection (signal sink, signal source) is displayed in the same index of p9498 and p9499.
p9497
BICO interconnections to deactivated drive objects number / Interconn obj qty
Access level:
3
Calculated:
-
Data type:
Unsigned16
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
0 65535
0
p9498[0...29]
BICO BI/CI parameters to deactivated drive objects / BI/CI to deact obj
Access level:
3
Calculated:
-
Data type:
Unsigned32
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
- - 0
p9499[0...29]
BICO BO/CO parameters to deactivated drive objects / BO/CO to deact obj
Access level:
3
Calculated:
-
Data type:
Unsigned32
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
- - 0
Содержание SINAMICS G120
Страница 1: ...SINAMICS SINAMICS G120 CU250S 2 Control Units List Manual 09 2017 Edition www siemens com drives ...
Страница 2: ......
Страница 726: ...2 Parameters 2 6 Quick commissioning p0010 1 SINAMICS G120 CU250S 2 Control Units 726 List Manual 09 2017 A5E33842890 ...
Страница 990: ...3 Function diagrams 3 26 Data sets SINAMICS G120 CU250S 2 Control Units 990 List Manual 09 2017 A5E33842890 ...
Страница 1242: ...A Appendix A 2 List of abbreviations SINAMICS G120 CU250S 2 Control Units 1242 List Manual 09 2017 A5E33842890 ...
Страница 1255: ......