2 Parameters
2.2 List of parameters
SINAMICS G120 CU250S-2 Control Units
570
List Manual, 09/2017, A5E33842890
Note:
For value = AC and DC hex:
These values can only be set if the safety commissioning mode is set and the Safety Integrated password was
entered.
Description:
Sets the signal source for the test stop of the safety-relevant motion monitoring functions.
Description:
Displays the actual load-side actual values of both monitoring channels and their difference.
Index:
[0] = Load-side actual value on the CU
[1] = Load-side actual value on the second channel
[2] = Load-side actual value difference CU - second channel
[3] = Load-side max. actual value difference CU - second channel
[4] = Load-side actual value as safe position via PROFIsafe
[5] = Load-side additional actual value difference CU - second channel
Dependency:
Refer to: r9713
Note:
For index 0:
The display of the load-side position actual value on processor 1 is updated in the monitoring clock cycle.
For index 1:
The display of the load-side position actual value on processor 2 is updated in the KDV clock cycle (r9724) and
delayed by one KDV clock cycle.
For index 2:
The difference between the load-side position actual value on processor 1 and load-side position actual value on
processor 2 is updated in the KDV clock cycle (r9724) and delayed by one KDV clock cycle.
For index 3:
The maximum difference between the load-side position actual value on processor 1 and the load-side position
actual value on processor 2.
For index 4:
The content corresponds to the value in index 0.
KDV: Data cross-check
Description:
Displays result list 1 that, for the data cross-check between the monitoring channels, led to the fault.
Index:
[0] = Result list processor 2
[1] = Result list processor 1
p9705
BI: SI Motion: Test stop signal source / SI Mtn test stop
Access level:
3
Calculated:
-
Data type:
U32 / Binary
Can be changed:
C(95)
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
2837
Min Max
Factory
setting
- - 0
r9708[0...5]
SI Motion diagnostics safe position / SI mtn safe pos
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
2822, 2836
Min Max
Factory
setting
- [°]
- [°]
- [°]
r9710[0...1]
SI Motion diagnostics result list 1 / SI Mtn res_list 1
Access level:
3
Calculated:
-
Data type:
Unsigned32
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
- - -
Bit field:
Bit
Signal name
1 signal
0 signal
FP
06
Actual value > upper limit SLS1
Yes
No
-
07
Actual value > lower limit SLS1
Yes
No
-
08
Actual value > upper limit SLS2
Yes
No
-
09
Actual value > lower limit SLS2
Yes
No
-
10
Actual value > upper limit SLS3
Yes
No
-
Содержание SINAMICS G120
Страница 1: ...SINAMICS SINAMICS G120 CU250S 2 Control Units List Manual 09 2017 Edition www siemens com drives ...
Страница 2: ......
Страница 726: ...2 Parameters 2 6 Quick commissioning p0010 1 SINAMICS G120 CU250S 2 Control Units 726 List Manual 09 2017 A5E33842890 ...
Страница 990: ...3 Function diagrams 3 26 Data sets SINAMICS G120 CU250S 2 Control Units 990 List Manual 09 2017 A5E33842890 ...
Страница 1242: ...A Appendix A 2 List of abbreviations SINAMICS G120 CU250S 2 Control Units 1242 List Manual 09 2017 A5E33842890 ...
Страница 1255: ......