SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890
705
2 Parameters
2.3 Command and drive data sets - overview
p0541[0...n]
Load gearbox code number / Load grbx CodeNo
p0542[0...n]
Load gearbox maximum speed / Load grbx n_max
p0543[0...n]
Load gearbox maximum torque / Load grbx M_max
p0544[0...n]
Load gearbox overall ratio (absolute value) numerator / Load grbx ratio N
p0545[0...n]
Load gearbox overall ratio (absolute value) denominator / Load grbx ratio D
p0546[0...n]
Load gearbox output direction of rotation inversion / Load grbx outp inv
p0550[0...n]
Brake type / Brake type
p0551[0...n]
Brake code number / Brake code no.
p0552[0...n]
Maximum brake speed / Brake n_max
p0553[0...n]
Brake holding torque / Brake M_hold
p0554[0...n]
Brake moment of inertia / Brake J
p0600[0...n]
Motor temperature sensor for monitoring / Mot temp_sensor
p0601[0...n]
Motor temperature sensor type / Mot_temp_sens type
p0604[0...n]
Mot_temp_mod 2/sensor alarm threshold / Mod 2/sens A_thr
p0605[0...n]
Mot_temp_mod 1/2/sensor threshold and temperature value / Mod1/2/sens T_thr
p0606[0...n]
Mot_temp_mod 2/sensor timer / Mod 2/sens timer
p0607[0...n]
Temperature sensor fault timer / Sensor fault time
p0610[0...n]
Motor overtemperature response / Mot temp response
p0611[0...n]
I2t motor model thermal time constant / I2t mot_mod T
p0612[0...n]
Mot_temp_mod activation / Mot_temp_mod act
p0613[0...n]
Mot_temp_mod 1/3 ambient temperature / Mod 1/3 amb_temp
p0614[0...n]
Thermal resistance adaptation reduction factor / Therm R_adapt red
p0615[0...n]
Mot_temp_mod 1 (I2t) fault threshold / I2t F thresh
p0620[0...n]
Thermal adaptation, stator and rotor resistance / Mot therm_adapt R
p0621[0...n]
Identification stator resistance after restart / Rst_ident Restart
p0622[0...n]
Motor excitation time for Rs_ident after switching on again / t_excit Rs_id
p0625[0...n]
Motor ambient temperature during commissioning / Mot T_ambient
p0626[0...n]
Motor overtemperature, stator core / Mot T_over core
p0627[0...n]
Motor overtemperature, stator winding / Mot T_over stator
p0628[0...n]
Motor overtemperature rotor / Mot T_over rotor
r0630[0...n]
Mot_temp_mod ambient temperature / Mod T_ambient
r0631[0...n]
Mot_temp_mod stator iron temperature / Mod T_stator
r0632[0...n]
Mot_temp_mod stator winding temperature / Mod T_winding
r0633[0...n]
Mot_temp_mod rotor temperature / Mod rotor temp
p0634[0...n]
Q flux flux constant unsaturated / PSIQ KPSI UNSAT
p0635[0...n]
Q flux quadrature axis current constant unsaturated / PSIQ KIQ UNSAT
p0636[0...n]
Q flux direct axis current constant unsaturated / PSIQ KID UNSAT
p0637[0...n]
Q flux flux gradient saturated / PSIQ Grad SAT
p0650[0...n]
Actual motor operating hours / Oper hours motor
p0651[0...n]
Motor operating hours maintenance interval / Mot t_op maint
p0826[0...n]
Motor changeover motor number / Mot_chng mot No.
p1231[0...n]
DC braking configuration / DCBRK config
p1232[0...n]
DC braking braking current / DCBRK I_brake
p1233[0...n]
DC braking time / DCBRK time
p1234[0...n]
Speed at the start of DC braking / DCBRK n_start
p1909[0...n]
Motor data identification control word / MotID STW
p1980[0...n]
PolID technique / PolID technique
p1999[0...n]
Ang. commutation offset calibr. and PollD scaling / Com_ang_offs scal
r3926[0...n]
Voltage generation alternating base voltage amplitude / U_gen altern base
p5350[0...n]
Mot_temp_mod 1/3 boost factor at standstill / Standst boost_fact
p5390[0...n]
Mot_temp_mod 1/3 alarm threshold / A thresh
p5391[0...n]
Mot_temp_mod 1/3 fault threshold / F thresh
r5398[0...n]
Mot_temp_mod 3 alarm threshold image p5390 / A thr image p5390
r5399[0...n]
Mot_temp_mod 3 fault threshold image p5391 / F thr image p5391
Содержание SINAMICS G120
Страница 1: ...SINAMICS SINAMICS G120 CU250S 2 Control Units List Manual 09 2017 Edition www siemens com drives ...
Страница 2: ......
Страница 726: ...2 Parameters 2 6 Quick commissioning p0010 1 SINAMICS G120 CU250S 2 Control Units 726 List Manual 09 2017 A5E33842890 ...
Страница 990: ...3 Function diagrams 3 26 Data sets SINAMICS G120 CU250S 2 Control Units 990 List Manual 09 2017 A5E33842890 ...
Страница 1242: ...A Appendix A 2 List of abbreviations SINAMICS G120 CU250S 2 Control Units 1242 List Manual 09 2017 A5E33842890 ...
Страница 1255: ......