SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890
465
2 Parameters
2.2 List of parameters
Description:
Successfully completed component of the last motor data identification carried out.
Dependency:
Refer to: r3925
Note:
The parameter is a copy of p1909.
Description:
Successfully completed component of the last rotating measurement carried out.
r3927[0...n]
Motor data identification control word / MotID STW
Access level:
3
Calculated:
p0340 = 1
Data type:
Unsigned32
Can be changed:
-
Scaling:
-
Dyn. index:
DDS, p0180
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
- - -
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Stator inductance estimate no
measurement
Yes
No
-
02
Rotor time constant estimate no
measurement
Yes
No
-
03
Leakage inductance estimate no
measurement
Yes
No
-
05
Determine Tr and Lsig evaluation in the time
range
Yes
No
-
06
Activate vibration damping
Yes
No
-
07
Deactivate vibration detection
Yes
No
-
11
Deactivate pulse measurement Lq Ld
Yes
No
-
12
Deactivate rotor resistance Rr
measurement
Yes
No
-
14
Deactivate valve interlocking time
measurement
Yes
No
-
15
Determine only stator resistance, valve
voltage fault, dead time
Yes
No
-
16
Short motor identification (lower quality)
Yes
No
-
17
Measurement without control parameter
calculation
Yes
No
-
18
After motID direct transition into operation
Yes
No
-
19
After MotID automatically save results
Yes
No
-
20
Estimate cable resistance
Yes
No
-
21
Calibrating the output voltage measurement Yes
No
-
22
Only identify circle
Yes
No
-
23
Deactivate circle identification
Yes
No
-
24
Circle identification with 0 and 90 degrees
Yes
No
-
r3928[0...n]
Rotating measurement configuration / Rot meas config
Access level:
3
Calculated:
p0340 = 1
Data type:
Unsigned16
Can be changed:
-
Scaling:
-
Dyn. index:
DDS, p0180
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
- - -
Bit field:
Bit
Signal name
1 signal
0 signal
FP
01
Saturation characteristic identification
Yes
No
-
02
Moment of inertia identification
Yes
No
-
03
Re-calculates the speed controller
parameters
Yes
No
-
04
Speed controller optimization (vibration test) Yes
No
-
05
q leakage inductance ident. (for current
controller adaptation)
Yes
No
-
11
Do not change the controller parameters
during the measurement
Yes
No
-
12
Measurement shortened
Yes
No
-
13
After measurement direct transition into
operation
Yes
No
-
14
Calculate speed actual value smooth. time
Yes
No
-
Содержание SINAMICS G120
Страница 1: ...SINAMICS SINAMICS G120 CU250S 2 Control Units List Manual 09 2017 Edition www siemens com drives ...
Страница 2: ......
Страница 726: ...2 Parameters 2 6 Quick commissioning p0010 1 SINAMICS G120 CU250S 2 Control Units 726 List Manual 09 2017 A5E33842890 ...
Страница 990: ...3 Function diagrams 3 26 Data sets SINAMICS G120 CU250S 2 Control Units 990 List Manual 09 2017 A5E33842890 ...
Страница 1242: ...A Appendix A 2 List of abbreviations SINAMICS G120 CU250S 2 Control Units 1242 List Manual 09 2017 A5E33842890 ...
Страница 1255: ......