SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890
89
2 Parameters
2.2 List of parameters
Description:
Sets the distance between two zero marks for a linear encoder.
This information is used for zero mark monitoring.
Notice:
This parameter is automatically pre-set for encoders from the encoder list (p0400). When selecting a catalog
encoder, this parameter cannot be changed (write protection). Information in p0400 should be carefully observed
when removing write protection.
Note:
For distance-coded zero marks, this means the basic distance.
Description:
Sets the distance in pulses between two zero marks for a rotary encoder. This information is used for zero mark
monitoring.
Notice:
This parameter is automatically pre-set for encoders from the encoder list (p0400).
When selecting a catalog encoder, this parameter cannot be changed (write protection). Information in p0400 should
be carefully observed when removing write protection.
Note:
For distance-coded zero marks, this means the basic distance.
Description:
Sets the differential distance with distance-coded zero marks [signal periods].
The value corresponds to jump displacement of "zero mark with interference".
Notice:
This parameter is automatically pre-set for encoders from the encoder list (p0400). When selecting a catalog
encoder, this parameter cannot be changed (write protection). Information in p0400 should be carefully observed
when removing write protection.
Description:
Sets the baud rate for an SSI encoder.
Notice:
This parameter is automatically pre-set for encoders from the encoder list (p0400). When selecting a catalog
encoder, this parameter cannot be changed (write protection). Information in p0400 should be carefully observed
when removing write protection.
Note:
SSI: Synchronous Serial Interface
p0424[0...n]
Encoder linear zero mark distance / Enc lin ZM_dist
Access level:
3
Calculated:
-
Data type:
Unsigned16
Can be changed:
C(4)
Scaling:
-
Dyn. index:
EDS, p0140
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
0 [mm]
65535 [mm]
20 [mm]
p0425[0...n]
Encoder rotary zero mark distance / Enc rot dist ZM
Access level:
3
Calculated:
-
Data type:
Unsigned32
Can be changed:
C(4)
Scaling:
-
Dyn. index:
EDS, p0140
Unit group:
-
Unit selection:
-
Func. diagram:
4704, 8570
Min Max
Factory
setting
0 16777215
2048
p0426[0...n]
Encoder zero mark differential distance / Enc ZM Dif_dist
Access level:
3
Calculated:
-
Data type:
Unsigned16
Can be changed:
C(4)
Scaling:
-
Dyn. index:
EDS, p0140
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
1 65535
1
p0427[0...n]
Encoder SSI baud rate / Enc SSI baud rate
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
C(4)
Scaling:
-
Dyn. index:
EDS, p0140
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
0 [kHz]
65535 [kHz]
100 [kHz]
Содержание SINAMICS G120
Страница 1: ...SINAMICS SINAMICS G120 CU250S 2 Control Units List Manual 09 2017 Edition www siemens com drives ...
Страница 2: ......
Страница 726: ...2 Parameters 2 6 Quick commissioning p0010 1 SINAMICS G120 CU250S 2 Control Units 726 List Manual 09 2017 A5E33842890 ...
Страница 990: ...3 Function diagrams 3 26 Data sets SINAMICS G120 CU250S 2 Control Units 990 List Manual 09 2017 A5E33842890 ...
Страница 1242: ...A Appendix A 2 List of abbreviations SINAMICS G120 CU250S 2 Control Units 1242 List Manual 09 2017 A5E33842890 ...
Страница 1255: ......