SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890
149
2 Parameters
2.2 List of parameters
Description:
Activates the absolute value generation for the analog outputs.
Value:
0:
No absolute value generation
1:
Absolute value generation switched in
Index:
[0] = AO0 (T 12/13)
[1] = AO1 (T 26/27)
Note:
AO: Analog Output
T: Terminal
Description:
Sets the analog output type.
p0776[x] = 1 corresponds to a voltage output (p0774, p0778, p0780 are displayed in V).
p0776[x] = 0, 2 corresponds to a current output (p0774, p0778, p0780 are displayed in mA).
Value:
0:
Current output (0 mA ... +20 mA)
1:
Voltage output (0 V ... +10 V)
2:
Current output (+4 mA ... +20 mA)
Index:
[0] = AO0 (T 12/13)
[1] = AO1 (T 26/27)
Note:
When changing p0776, the parameters of the scaling characteristic (p0777, p0778, p0779, p0780) are overwritten
with the following default values:
For p0776 = 0, p0777 is set to 0.0 %, p0778 = 0.0 mA, p0779 = 100.0 % and p0780 to 20.0 mA.
For p0776 = 1, p0777 is set to 0.0 %, p0778 = 0.0 V, p0779 = 100.0 % and p0780 to 10.0 V.
For p0776 = 2, p0777 is set to 0.0 %, p0778 = 4.0 mA, p0779 = 100.0 % and p0780 to 20.0 mA.
Description:
Sets the scaling characteristic for the analog outputs.
The scaling characteristic for the analog outputs is defined using 2 points.
This parameter specifies the x coordinate (percentage) of the 1st value pair of the characteristic.
Index:
[0] = AO0 (T 12/13)
[1] = AO1 (T 26/27)
Dependency:
Refer to: p0776
Notice:
This parameter is automatically overwritten when changing p0776 (type of analog outputs).
Note:
The parameters for the characteristic do not have a limiting effect.
p0775[0...1]
CU analog outputs activate absolute value generation / CU AO absVal act
Access level:
2
Calculated:
-
Data type:
Integer16
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
9572
Min Max
Factory
setting
0 1 0
p0776[0...1]
CU analog outputs type / CU AO type
Access level:
2
Calculated:
-
Data type:
Integer16
Can be changed:
U, T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
9572
Min Max
Factory
setting
0 2 0
p0777[0...1]
CU analog outputs characteristic value x1 / CU AO char x1
Access level:
2
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
U, T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
9572
Min Max
Factory
setting
-1000.00 [%]
1000.00 [%]
0.00 [%]
Содержание SINAMICS G120
Страница 1: ...SINAMICS SINAMICS G120 CU250S 2 Control Units List Manual 09 2017 Edition www siemens com drives ...
Страница 2: ......
Страница 726: ...2 Parameters 2 6 Quick commissioning p0010 1 SINAMICS G120 CU250S 2 Control Units 726 List Manual 09 2017 A5E33842890 ...
Страница 990: ...3 Function diagrams 3 26 Data sets SINAMICS G120 CU250S 2 Control Units 990 List Manual 09 2017 A5E33842890 ...
Страница 1242: ...A Appendix A 2 List of abbreviations SINAMICS G120 CU250S 2 Control Units 1242 List Manual 09 2017 A5E33842890 ...
Страница 1255: ......