SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890
423
2 Parameters
2.2 List of parameters
Description:
Sets the signal source for "external block change".
BI: p2633 = 0/1 signal
Dependency:
The evaluation of the signal is only active p2632 = 1.
Refer to: p2623, p2632, p2640, p2641, r2677, r2678
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note:
A 0/1 edge initiates a flying block change in the subsequent traversing block.
When the external block change is identified, the actual position is saved in r2678.
A traversing task can be influenced using the following signals:
- intermediate stop via BI: p2640.
- reject traversing task via BI: p2641.
Description:
Sets the following error to detect the "fixed stop reached" state (r2526.4).
Dependency:
Refer to: r2526, p2621, r2675
Note:
The state "fixed stop reached" is detected if the following error exceeds the theoretically calculated following error
value by p2634.
Description:
Sets the monitoring window of the actual position after the fixed stop is reached.
Dependency:
Refer to: r2526, r2683
Refer to: F07484
Note:
If, after the fixed stop is reached, the end stop shifts in either the positive or negative direction by more than the value
set here, then BO: r2526.5 is set to 1 and an appropriate message is output.
p2633
BI: EPOS external block change (0 -> 1) / Ext BlckChg (0->1)
CU250S_V (EPOS)
CU250S_V_CAN
(EPOS)
CU250S_V_DP
(EPOS)
CU250S_V_PN
(EPOS)
Access level:
1
Calculated:
-
Data type:
U32 / Binary
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
3615
Min Max
Factory
setting
- - 0
p2634[0...n]
EPOS fixed stop maximum following error / Following err max
CU250S_V (Position
control)
CU250S_V_CAN
(Position control)
CU250S_V_DP
(Position control)
CU250S_V_PN
(Position control)
Access level:
1
Calculated:
-
Data type:
Unsigned32
Can be changed:
U, T
Scaling:
-
Dyn. index:
DDS, p0180
Unit group:
-
Unit selection:
-
Func. diagram:
3617, 4025
Min Max
Factory
setting
0 [LU]
2147482647 [LU]
1000 [LU]
p2635
EPOS fixed stop monitoring window / Fixed stop monit
CU250S_V (Position
control)
CU250S_V_CAN
(Position control)
CU250S_V_DP
(Position control)
CU250S_V_PN
(Position control)
Access level:
1
Calculated:
-
Data type:
Unsigned32
Can be changed:
U, T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
3617, 4025
Min Max
Factory
setting
0 [LU]
2147482647 [LU]
100 [LU]
Содержание SINAMICS G120
Страница 1: ...SINAMICS SINAMICS G120 CU250S 2 Control Units List Manual 09 2017 Edition www siemens com drives ...
Страница 2: ......
Страница 726: ...2 Parameters 2 6 Quick commissioning p0010 1 SINAMICS G120 CU250S 2 Control Units 726 List Manual 09 2017 A5E33842890 ...
Страница 990: ...3 Function diagrams 3 26 Data sets SINAMICS G120 CU250S 2 Control Units 990 List Manual 09 2017 A5E33842890 ...
Страница 1242: ...A Appendix A 2 List of abbreviations SINAMICS G120 CU250S 2 Control Units 1242 List Manual 09 2017 A5E33842890 ...
Страница 1255: ......