SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890
547
2 Parameters
2.2 List of parameters
15:
[0F hex] Acc_mode not possible due to expired Acc_timer
172:
[AC hex] Acc_mode active
Dependency:
Refer to: p9358, p9370
Refer to: C01799
Description:
Sets the reference value to define the brake ramp.
The rate of rise of the brake ramp depends upon p9381 (reference value) and p9383 (monitoring time).
Dependency:
Refer to: p9382, p9383
Notice:
This parameter is overwritten by the copy function of the safety functions integrated in the drive.
Description:
Sets the delay time for monitoring the brake ramp.
Monitoring of the brake ramp starts once the delay time has elapsed.
Dependency:
Refer to: p9381, p9383
Notice:
This parameter is overwritten by the copy function of the safety functions integrated in the drive.
Note:
The set time is rounded internally to an integer multiple of the monitoring clock cycle.
Internally, the set time is limited downwards to 2 safety monitoring clock cycles (2 * 12 ms).
Description:
Sets the monitoring time to define the brake ramp.
The rate of rise of the brake ramp depends upon p9381 (reference value) and p9383 (monitoring time).
Dependency:
Refer to: p9381, p9382
Notice:
This parameter is overwritten by the copy function of the safety functions integrated in the drive.
Note:
The set time is rounded internally to an integer multiple of the monitoring clock cycle.
Description:
Sets the tolerance of the plausibility monitoring of the current and voltage angle.
A higher value results in a higher degree of ruggedness when reversing at low speeds, as well as in the field
weakening range for load steps.
An increase is advantageous, if the current or voltage at the motor become small.
Dependency:
Refer to: p9507
Refer to: F30681, C30711
p9381
SI Motion brake ramp reference value (processor 2) / SI Mtn ramp ref P2
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
C(95)
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
600.0000 [rpm]
240000.0000 [rpm]
1500.0000 [rpm]
p9382
SI Motion brake ramp delay time (processor 2) / SI Mtn rp t_del P2
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
C(95)
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
10000.00 [µs]
99000000.00 [µs]
250000.00 [µs]
p9383
SI Motion brake ramp monitoring time (processor 2) / SI Mtn rp t_mon P2
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
C(95)
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
500.00 [ms]
3600000.00 [ms]
10000.00 [ms]
p9385
SI Motion actual value sensing sensorless fault tolerance (MM) / ActVal sl tol MM
Access level:
3
Calculated:
-
Data type:
Integer32
Can be changed:
C(95)
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
-1 4 -1
Содержание SINAMICS G120
Страница 1: ...SINAMICS SINAMICS G120 CU250S 2 Control Units List Manual 09 2017 Edition www siemens com drives ...
Страница 2: ......
Страница 726: ...2 Parameters 2 6 Quick commissioning p0010 1 SINAMICS G120 CU250S 2 Control Units 726 List Manual 09 2017 A5E33842890 ...
Страница 990: ...3 Function diagrams 3 26 Data sets SINAMICS G120 CU250S 2 Control Units 990 List Manual 09 2017 A5E33842890 ...
Страница 1242: ...A Appendix A 2 List of abbreviations SINAMICS G120 CU250S 2 Control Units 1242 List Manual 09 2017 A5E33842890 ...
Страница 1255: ......