2 Parameters
2.2 List of parameters
Description:
Sets the relative positioning mode for flying referencing.
Value = 1:
The corrected setpoint is not calculated into the traversing distance.
Value = 0:
The corrected setpoint is calculated into the traversing distance.
Dependency:
Refer to: p2597, p2623, p2648
Notice:
For p2603 = 0 the direction can change.
Description:
Sets the signal sources for the start direction of the search for reference.
1 signal: Start in the negative direction.
0 signal: Start in the positive direction.
Dependency:
Refer to: p2583, p2595, p2597
Description:
Sets the approach velocity to the reference cam for the search for reference.
Dependency:
The search for reference only starts with the approach velocity to the reference cam when there is a reference cam
(p2607 = 1).
Refer to: p2595, p2597, p2604, p2606, p2607
Note:
When traversing to the reference cam, the velocity override is effective.
If, at the start of the search for reference, the axis is already at the reference cam, then the axis immediately starts to
traverse to the zero mark.
Description:
Sets the maximum distance after the start of the search for reference when traversing to the reference cam.
Dependency:
Refer to: p2595, p2597, p2604, p2605, p2607
Refer to: F07458
p2603
EPOS flying referencing, positioning mode relative / Pos_mode relative
CU250S_V (EPOS)
CU250S_V_CAN
(EPOS)
CU250S_V_DP
(EPOS)
CU250S_V_PN
(EPOS)
Access level:
1
Calculated:
-
Data type:
Integer32
Can be changed:
U, T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
3635
Min Max
Factory
setting
0 1 1
p2604
BI: EPOS search for reference start direction / Srch for ref dir
CU250S_V (EPOS)
CU250S_V_CAN
(EPOS)
CU250S_V_DP
(EPOS)
CU250S_V_PN
(EPOS)
Access level:
1
Calculated:
-
Data type:
U32 / Binary
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
3612
Min Max
Factory
setting
- - 0
p2605
EPOS search for reference approach velocity reference cam / v_appr ref_cam
CU250S_V (EPOS)
CU250S_V_CAN
(EPOS)
CU250S_V_DP
(EPOS)
CU250S_V_PN
(EPOS)
Access level:
1
Calculated:
-
Data type:
Unsigned32
Can be changed:
U, T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
3612
Min Max
Factory
setting
1 [1000 LU/min]
40000000 [1000 LU/min]
5000 [1000 LU/min]
p2606
EPOS search for reference reference cam maximum distance / Ref_cam max s
CU250S_V (EPOS)
CU250S_V_CAN
(EPOS)
CU250S_V_DP
(EPOS)
CU250S_V_PN
(EPOS)
Access level:
1
Calculated:
-
Data type:
Unsigned32
Can be changed:
U, T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
3612
Min Max
Factory
setting
0 [LU]
2147482647 [LU]
2147482647 [LU]
Содержание SINAMICS G120
Страница 1: ...SINAMICS SINAMICS G120 CU250S 2 Control Units List Manual 09 2017 Edition www siemens com drives ...
Страница 2: ......
Страница 726: ...2 Parameters 2 6 Quick commissioning p0010 1 SINAMICS G120 CU250S 2 Control Units 726 List Manual 09 2017 A5E33842890 ...
Страница 990: ...3 Function diagrams 3 26 Data sets SINAMICS G120 CU250S 2 Control Units 990 List Manual 09 2017 A5E33842890 ...
Страница 1242: ...A Appendix A 2 List of abbreviations SINAMICS G120 CU250S 2 Control Units 1242 List Manual 09 2017 A5E33842890 ...
Страница 1255: ......