Sig
nals an
d mon
ito
rin
g
fu
nctions
F
ig.
3
-215
80
18 – Mo
to
r
tempera
tu
re
mod
el 2
- 8018 -
Function diagram
8
7
6
5
4
3
2
1
fp_8018_97_61.vsd
Signals and monitoring functions
G120 CU250S-2
05.09.2017
V4.7.9
Motor temperature model 2
[8016.1]
p0612.1 (1)
1 = Activate motor
temperature model 2
Mot T_ambient
p0625
Mot T_over core
p0626
Mot T_over stator
p0627
Mot T_over rotor
p0628
Mod T_ambient [°C]
r0630 [M]
Mod T_stator [°C]
r0631 [M]
Mod T_winding [°C]
r0632 [M]
Mod rotor temp [°C]
r0633 [M]
Calculated motor temperatures
Rated motor temperature rise
If p0610 = 12.
<1>
p0612.9 (1)
1 = Activate motor temperature
model 2 expansions
Motor temperature model 2 (Thermal 3-mass-model)
Only for:
Induction motor (ASM)
Mot temp response
p0610
Mot weight th mod
p0344
<1>
Содержание SINAMICS G120
Страница 1: ...SINAMICS SINAMICS G120 CU250S 2 Control Units List Manual 09 2017 Edition www siemens com drives ...
Страница 2: ......
Страница 726: ...2 Parameters 2 6 Quick commissioning p0010 1 SINAMICS G120 CU250S 2 Control Units 726 List Manual 09 2017 A5E33842890 ...
Страница 990: ...3 Function diagrams 3 26 Data sets SINAMICS G120 CU250S 2 Control Units 990 List Manual 09 2017 A5E33842890 ...
Страница 1242: ...A Appendix A 2 List of abbreviations SINAMICS G120 CU250S 2 Control Units 1242 List Manual 09 2017 A5E33842890 ...
Страница 1255: ......