2 Parameters
2.2 List of parameters
SINAMICS G120 CU250S-2 Control Units
288
List Manual, 09/2017, A5E33842890
Description:
Sets the integral time of the controller for speed adaptation without encoder
Dependency:
Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
Description:
Displays the effective gain of the integral component of the controller for speed adaptation.
Dependency:
Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1), "Dynamic Drive Control" (DDC, p0096
= 2)
Description:
Sets the wait time for a transition from open-loop controlled to closed-loop controlled operation after twice the lower
changeover speed p1755 * (1 - p1756 / 100 %) has been exceeded - and below the upper switchover speed p1755.
Dependency:
Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
Refer to: p1755, p1756
Note:
With p1759 = 0 ms and above p1755, the delay time becomes ineffective and the model changeover is determined
by the output frequency only (changeover for p1755).
Description:
Displays the P component of the controller for speed adaptation.
Dependency:
Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
Description:
Displays the I component of the controller for speed adaptation.
Dependency:
Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
p1767[0...n]
Motor model without encoder speed adaptation Tn / MotMod woE n_adaTn
Access level:
4
Calculated:
p0340 = 1,3,4
Data type:
FloatingPoint32
Can be changed:
U, T
Scaling:
-
Dyn. index:
DDS, p0180
Unit group:
-
Unit selection:
-
Func. diagram:
6730
Min Max
Factory
setting
1 [ms]
200 [ms]
4 [ms]
r1768
Motor model speed adaptation Vi effective / MotM n_ada Vi act
Access level:
4
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
-
Scaling:
p2001
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
- - -
p1769[0...n]
Motor model changeover delay time closed-loop control / MotMod t cl_ctrl
Access level:
4
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
U, T
Scaling:
-
Dyn. index:
DDS, p0180
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
0 [ms]
10000 [ms]
0 [ms]
r1770
CO: Motor model speed adaptation proportional component / MotMod n_adapt Kp
Access level:
4
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
-
Scaling:
p2000
Dyn. index:
-
Unit group:
3_1
Unit selection:
p0505
Func. diagram:
6730
Min Max
Factory
setting
- [rpm]
- [rpm]
- [rpm]
r1771
CO: Motor model speed adaptation I comp. / MotMod n_adapt Tn
Access level:
4
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
-
Scaling:
p2000
Dyn. index:
-
Unit group:
3_1
Unit selection:
p0505
Func. diagram:
6730
Min Max
Factory
setting
- [rpm]
- [rpm]
- [rpm]
Содержание SINAMICS G120
Страница 1: ...SINAMICS SINAMICS G120 CU250S 2 Control Units List Manual 09 2017 Edition www siemens com drives ...
Страница 2: ......
Страница 726: ...2 Parameters 2 6 Quick commissioning p0010 1 SINAMICS G120 CU250S 2 Control Units 726 List Manual 09 2017 A5E33842890 ...
Страница 990: ...3 Function diagrams 3 26 Data sets SINAMICS G120 CU250S 2 Control Units 990 List Manual 09 2017 A5E33842890 ...
Страница 1242: ...A Appendix A 2 List of abbreviations SINAMICS G120 CU250S 2 Control Units 1242 List Manual 09 2017 A5E33842890 ...
Страница 1255: ......