Description:
CRC via Node Identifier of the Control Unit.
Note:
CU: Control Unit
Description:
CRC via the Node Identifier of a Power Module.
Note:
PM: Power Module
Description:
Setting to start the required copy function.
After starting, the corresponding parameters are copied from processor 1 to processor 2.
Once copying is complete, the parameter is automatically reset to zero.
Value:
0:
[00 hex] Copy function ended
29:
[1D hex] Start copy function node identifier
87:
[57 hex] Start copy function SI parameters
208:
[D0 hex] Start copy function SI basic parameters
Dependency:
Refer to: r3996
Notice:
When the parameters are copied, short-term communication interruptions may occur.
Note:
For value = 57 hex and D0 hex:
The value can only be set if the safety commissioning mode is set and the Safety Integrated password was entered.
For value = D0 hex:
The following parameters are copied after starting the copy function:
p9601 --> p9801, p9610 --> 9810, p9650 --> p9850, p9651 --> p9851
Description:
Setting to transfer the reference checksums from the associated actual checksums after changes (SI parameters,
hardware).
After transferring the reference checksums, parameters are automatically reset to zero.
Value:
0:
[00 hex] Data unchanged
172:
[AC hex] Acknowledge data change complete
220:
[DC hex] Acknowledge SI basic parameter change
236:
[EC hex] Acknowledge hardware CRC
Dependency:
Refer to: r9398, p9399, r9728, p9729, r9798, p9799, r9898, p9899
p9670
SI module identification Control Unit / Module ID CU
Access level:
3
Calculated:
-
Data type:
Unsigned32
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
0 4294967295
0
p9672
SI module identifier Power Module / Module ID PM
Access level:
3
Calculated:
-
Data type:
Unsigned32
Can be changed:
C(95), T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
0 4294967295
0
p9700
SI copy function / SI copy function
Access level:
3
Calculated:
-
Data type:
Integer16
Can be changed:
C(95), U, T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
0000 hex
00D0 hex
0000 hex
p9701
Acknowledge SI data change / Ackn SI data
Access level:
3
Calculated:
-
Data type:
Integer16
Can be changed:
C(95), U, T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
0000 hex
00EC hex
0000 hex
Содержание SINAMICS G120
Страница 1: ...SINAMICS SINAMICS G120 CU250S 2 Control Units List Manual 09 2017 Edition www siemens com drives ...
Страница 2: ......
Страница 726: ...2 Parameters 2 6 Quick commissioning p0010 1 SINAMICS G120 CU250S 2 Control Units 726 List Manual 09 2017 A5E33842890 ...
Страница 990: ...3 Function diagrams 3 26 Data sets SINAMICS G120 CU250S 2 Control Units 990 List Manual 09 2017 A5E33842890 ...
Страница 1242: ...A Appendix A 2 List of abbreviations SINAMICS G120 CU250S 2 Control Units 1242 List Manual 09 2017 A5E33842890 ...
Страница 1255: ......