2 Parameters
2.1 Overview of parameters
SINAMICS G120 CU250S-2 Control Units
18
List Manual, 09/2017, A5E33842890
Dyn. index (dynamic index)
For parameters with a dynamic index [0...n], the following information is specified here:
•
Data set (if available).
•
Parameter for the number of indices (n = number - 1).
The following information can be contained in this field:
•
"CDS, p0170" (Command Data Set, CDS count)
Example:
p1070[0]
main setpoint [command data set 0]
p1070[1]
main setpoint [command data set 1], etc.
•
"DDS, p0180" (Drive Data Set, DDS count)
•
"EDS, p0140" (Encoder Data Set, EDS count)
•
"MDS, p0130" (Motor Data Set, MDS count)
•
"PDS, p0120" (Power unit Data Set, PDS count)
Data sets can only be created and deleted when p0010 = 15.
Unit group and unit selection
The standard unit of a parameter is specified in square parentheses after the values for "Min",
"Max", and "Factory setting".
For parameters where the unit can be switched over, the specifications for "Unit group" and
"Unit selection" determine the group to which this parameter belongs and with which parameter
the unit can be switched over.
Example:
Unit group: 7_1, unit selection: p0505
The parameter belongs to unit group 7_1 and the unit can be switched over using p0505.
All the potential unit groups and possible unit selections are listed below.
Note
Information on the data sets can be taken from the following references:
•
Operating Instructions SINAMICS G120 Frequency Inverter with CU250S-2 Control Units.
Table 2-3
Unit group (p0100)
Unit group
Unit Choice for p0100 =
Reference variable for %
0
1
2
7_4
Nm
lbf ft
Nm
-
14_6
kW
hp
kW
-
25_1
kg m
2
lb ft
2
kg m
2
-
27_1
kg
lb
kg
-
28_1
Nm/A
lbf ft/A
Nm/A
-
Содержание SINAMICS G120
Страница 1: ...SINAMICS SINAMICS G120 CU250S 2 Control Units List Manual 09 2017 Edition www siemens com drives ...
Страница 2: ......
Страница 726: ...2 Parameters 2 6 Quick commissioning p0010 1 SINAMICS G120 CU250S 2 Control Units 726 List Manual 09 2017 A5E33842890 ...
Страница 990: ...3 Function diagrams 3 26 Data sets SINAMICS G120 CU250S 2 Control Units 990 List Manual 09 2017 A5E33842890 ...
Страница 1242: ...A Appendix A 2 List of abbreviations SINAMICS G120 CU250S 2 Control Units 1242 List Manual 09 2017 A5E33842890 ...