SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890
477
2 Parameters
2.2 List of parameters
Description:
Sets the positive tolerance window in encoder pulses for limit 2 for the zero mark monitoring.
Accumulator (p4688) is compared with this parameter, and where relevant, alarm A3x422 is output for 5 seconds.
Dependency:
Refer to: p0437, p4681, p4682, p4688
Refer to: F31131, A31422
Note:
Zero mark monitoring is activated by setting p0437.2 = 1 (position actual value correction).
Description:
Sets the negative tolerance window in encoder pulses for limit 2 for the zero mark monitoring.
Accumulator (p4688) is compared with this parameter, and where relevant, alarm A3x422 is output for 5 seconds.
Dependency:
Refer to: p0437, p4683, p4688
Refer to: F31131, A31422
Note:
Zero mark monitoring is activated by setting p0437.2 = 1 (position actual value correction).
For a set value = -100001, the negated value of p4683 is effective.
Description:
Sets the number of current controller clock cycles for mean value generation of the speed actual value.
Note:
Value = 0, 1: No mean value generation.
Higher values also mean higher dead times for the speed actual value.
Description:
Sets the minimum length for the zero mark in 1/4 encoder pulses.
Dependency:
Refer to: p0425, p0437
Note:
The minimum length of the zero mark must be less than the zero mark distance (p4686 < p0425).
The parameter is activated using p0437.1 = 1 (zero mark edge detection).
p4683[0...n]
Zero mark monitoring tolerance window alarm threshold positive / ZM tol A_thr pos
Access level:
3
Calculated:
-
Data type:
Unsigned32
Can be changed:
C(4)
Scaling:
-
Dyn. index:
EDS, p0140
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
0 100000
0
p4684[0...n]
Zero mark monitoring tolerance window alarm threshold negative / ZM tol A_thr neg
Access level:
3
Calculated:
-
Data type:
Integer32
Can be changed:
C(4)
Scaling:
-
Dyn. index:
EDS, p0140
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
-100001 0
-100001
p4685[0...n]
Speed actual value mean value generation / n_act mean val
Access level:
3
Calculated:
-
Data type:
Unsigned32
Can be changed:
C(4)
Scaling:
-
Dyn. index:
EDS, p0140
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
0 20
0
p4686[0...n]
Zero mark minimum length / ZM min length
Access level:
3
Calculated:
-
Data type:
Unsigned32
Can be changed:
C(4)
Scaling:
-
Dyn. index:
EDS, p0140
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
0 10
1
Содержание SINAMICS G120
Страница 1: ...SINAMICS SINAMICS G120 CU250S 2 Control Units List Manual 09 2017 Edition www siemens com drives ...
Страница 2: ......
Страница 726: ...2 Parameters 2 6 Quick commissioning p0010 1 SINAMICS G120 CU250S 2 Control Units 726 List Manual 09 2017 A5E33842890 ...
Страница 990: ...3 Function diagrams 3 26 Data sets SINAMICS G120 CU250S 2 Control Units 990 List Manual 09 2017 A5E33842890 ...
Страница 1242: ...A Appendix A 2 List of abbreviations SINAMICS G120 CU250S 2 Control Units 1242 List Manual 09 2017 A5E33842890 ...
Страница 1255: ......