UMS-02 Series Controllers are universal programmable time controllers.
The main application of these controllers is to control external devices within the process of washing the
milk and milking room coolers.
The controllers casing is designed to be built in.
CONTROLLER’S FUNCTIONS
1.
Washing programs.
The controller has 8 washing programs. Factory settings include 2 milking room washing
programs and 2 programs to wash the coolers. The remaining programs are to be programmed by
the installer.
2.
Programs setting and modification function.
The controller enables (the installer) to individually set the programs. Each program can include
up to 50 steps and can last up to 99 minutes. The programming is very simple and intuitive. It is
shown in detail in the manual in the form of pictures. The factory set programs can also be
modified according to specific needs.
3.
Safety function in case of power outage.
In case of power outage the set program is stopped. When the power is back, the program will be
restarted at the same point it was at the moment the outage occurred. When setting this function,
it is possible to restrict the time, from 1 to 9 hours, in which it is possible to return to the
interrupted operation performed by the controller.
4.
Service function enabling to test the correctness of work of the controller set.
This function allows to go to the next sequences of a program without waiting for the time to
pass. Skipping the stages is done by means of pressing a special button. This function is only
available for the installer.
5.
Function allowing to return to factory settings.
In case an error occurs when setting the controller’s work program, there is always a possibility to
return to factory settings.
6.
Function enabling to manually switch on the subpressure pump or the agitator.
7.
Function enabling to start a program.
The program starts when a button located on the face of the controller is pressed manually or
when an external button attached to the controller is pressed. It is also possible to start the
program in an automatic way through an external device.
8.
Pause function. This function enables to stop the running of a program at any time until it is
restarted. The restart causes the program to start operating at the same point when it stopped. The
pause function can be enabled by pressing a located on the face of the controller or by pressing an
external button attached to the controller.
9.
Function switching the program off.
The controller is equipped with a button which enables to switch the program off without the
possibility to restart it at the same point. When the program is restarted it will start the program
from the very beginning.
10.
Time remaining function. When the program is running the remaining time is visible on the
display. The time presented doesn’t include the time required to pour the water in.
11.
Function showing the process of pouring the water in is finished, depending on the hydrostat
UMS-02 Controller is equipped with:
6 controller leads:
- one lead (relay No. 5) is equipped with contacts: normal close and normal open;
- all the other leads have normal open contacts;
- switched power input is conducted to enable providing any kind of power between 6 and
380 V
hydrostat input
input allowing to connect an external program starting button;
PRZEDSIĘBIORSTWO
PRODUKCYJNO HANDLOWE
MANUAL
CONTROLLER
SERIES
UMS-02
30-716 KRAKÓW
ul.Przewóz 34/304
tel 012 657 91 44
Содержание UMS-02