background image

November, 2003 

455 D Control 

Panel Installation 

Instructions 

CONTENTS 

General Description 

Installing the 455 D Control Panel         

Connect the Main Power Supply 

Connect the Operator(s) to the Control Panel 

Check the Motor’s Direction of Rotation 

Connect Other Devices 

Set Other Operating Controls 

Programming 8 

Learning of Operating Times 

10 

Learning of Normal Times 

10 

Learning Times with Gatecoder 

10 

Automated System Test 

11 

Logic Tables of 455 D Control Panel 

12 

Safety in Gate Design       

14 

Maintenance 14 

Limited Warranty 

16 

T

H E

  4 5 5   D   C

O N T R O L

  P

A N E L

:    

S

U P P L E M E N T A L

  I

N S T A L L A T I O N

 

I

N S T R U C T I O N S

     

FAAC International, Inc. 
303 Lexington Avenue 
Cheyenne, WY  82007 
www.faacusa.com 

Note

: These instructions supplement the 

installation manual for your operator. Be 

sure to review all safety information in the 
installation manual for your operator. 

Содержание 455 D

Страница 1: ...es 10 Learning of Normal Times 10 Learning Times with Gatecoder 10 Automated System Test 11 Logic Tables of 455 D Control Panel 12 Safety in Gate Design 14 Maintenance 14 Limited Warranty 16 T H E 4 5...

Страница 2: ...reaker switch and for making sure that the entire gate system meets all applicable electrical codes The installer should refer to the installation manual for a given operator for more information NOTE...

Страница 3: ...e each leg of the capacitor supplied to terminals 2 3 Note If you want to delay the closing of one gate leaf in a two leaf gate design be sure to connect its operator to Motor 1 In order to wire motor...

Страница 4: ...pplying power to accessories through terminals 17 or 18 and 14 or 15 or 16 on terminal block J1 In most cases this source can be used to power 24 VDC accessories NOTE The 455 D control panel allows a...

Страница 5: ...OP_B Partial Opening should illuminate only when an activating signal is sent for 2 and 1 gate leaves respectively STOP should be illuminated except when the stop button is pressed FSWOP and FSWCL sh...

Страница 6: ...is set at less than the leaf delay time the delayed leaf closes at the end of the closing time Page 6 November 2003 455 D Control Panel Installation Instructions opening and closing respectively are...

Страница 7: ...ls f or opening 1 2 1 2 3 4 5 17 13 19 14 17 Additional Reversing Devices TX RX 1 2 1 2 3 4 5 19 17 12 19 17 Additional Reversing Devices TX RX 1 2 19 12 17 15 Additional Reversing Devices 8 7 Safety...

Страница 8: ...and if you release it the value that can be modified with keys and When you reach the last function press the F key to exit the program and the display resumes showing the status of the inputs The tab...

Страница 9: ...ed the output functions as a standard indicator light lighted at opening and pause flashing at closing and off when gate closed Different figures correspond to timed activation of the output which can...

Страница 10: ...automatically when the opening positive stop is reached and the display stops flashing The procedure has ended and the gate is ready to operate using default slow down automatically set by the control...

Страница 11: ...top the operator will automatically shut off An open command must be given to start closing gate operator 2 When gate operator 2 reaches the position that you want it to slow down an open command must...

Страница 12: ...t Closed Opens both leaves and closes them after pause time Opens single leaf connected to Motor 1 and closes it after pause time No effect No effect No effect Off Opening Closes both leaves Closes le...

Страница 13: ...or 1 No effect opening is inhibited No effect opening is inhibited No effect opening is inhibited Off Opening Stops Stops Stops Stops gate closes when reversing device no longer trig gered No effect O...

Страница 14: ...rians should not use a vehicular gate system Prevent such inappropriate use by installing separate gates for pedestrians The operating controls for an automatic gate must be secured to prevent the una...

Страница 15: ...Page 15 November 2003 455 D Control Panel Installation Instructions This page is left blank intentionally...