background image

GEM

     

DG-2000 Series Standalone PROX Reader Controller Operation Manual

__________________________________________________________________________

_______________________________________________________________________________________________________________      
Version 

1. 

05-22-2015 

  Gianni 

Industries, Inc. 

 

                                 Page 1 of 

17

 

1. FEATURES 

2. TECHNICAL SPECIFICATIONS 

3. INSTALLATION DIAGRAMS 

4. PARAMETERS SETUP 

Enter and Exit the program mode 

Reset to factory setting 

Change master password

Change door common access password

Setup operation mode 

Setup current time 

Setup time interval function of electrified lock released

Setup time interval function of No password entry needed

Setup time interval function for disabling alarm

Enable time interval function of No password entry needed (option)

Enable time interval function of disabling alarm (option)

Enable time interval function of electrified lock released (option)

Enable door ajar function 

Enable alarm function 

5. Adding Card and Door Access PIN

Add master card 

Add user card 

Add door access PIN

6. Deleting Card and Door Access PIN

Delete master card 

Delete user card 

Delete door access PIN

Empty location ID 

Delete all master cards 

Delete all user cards 

Delete all door access PINs

7. USERS LIST

8. NOTES

9. HOW TO ORDER

Содержание DG-2000 Series

Страница 1: ...ode Setup current time Setup time interval function of electrified lock released Setup time interval function of No password entry needed Setup time interval function for disabling alarm Enable time interval function of No password entry needed option Enable time interval function of disabling alarm option Enable time interval function of electrified lock released option Enable door ajar function ...

Страница 2: ...card and to enter the program mode The Master card is also equal to a valid access card 2000 cardholder capacity 32 bit card serial number which can be saved at a memory location from 1 to 2000 200 Door Access PINs The length of a PIN number is capable from 1 to 6 digits and you can set the value from 0 to 999999 A PIN number can be saved at a memory location from 2001 to 2200 1 Common Access Pass...

Страница 3: ...eturn to programming mode 3 Access denied Invalid password Invalid value entry 4 Power on Reset to factory setting Door Ajar Get a single beep for every 2 seconds until door sensor closed Sound Duration Beep Volume n o i t p i r c s e D Short 10ms Medium 20ms Long 40ms DG 2100K Red Flashing Yellow Green Flashing Green DG 2000US DG 2100EU DG 2000R DG 2000K DG 2000SR DG 2100R Power Voltage 12 to 16 ...

Страница 4: ...PSM 25T Optional Reader DG 2000US EM Mifare Stand Alone Power Supply or DG 2100EU Inside EXIT ENTRY Outside DG 2000K or DG 2100K Built in locking timer controller Two Technology In One Keypad Controller EM Low Frequency Mifare High Frequency Prox Reader Controller Normal Mode Power Supply PSU310 DG 2000US EM Mifare Standalone Request to Exit Button PBT 800 or AS 500 or DG 2100EU Inside EXIT ENTRY ...

Страница 5: ...5 of 17 Electrified Locks Applications GEM 800 Magnetic Lock 800 lbs GK300 Electric Strike EB220N Electric Dropbolt EB261 Fail Secure Electric Latch Bolt GK530 540 European Profile Strike LS2200 Latch Bolt http www gianni com tw ElectromagneticLock gem800 asp http www gianni com tw ElectricStrike gk300 asp http www gianni com tw ElectricDropbolt eb220n asp http www gianni com tw ElectricDropbolt e...

Страница 6: ...UZZER P1 4 Green LED For external reader GREEN LED P1 5 D0 For external reader Data 0 P1 6 D1 For external reader Data 1 P1 7 Earth Ground For external reader Earth Ground P1 8 Power For external reader Power PIN Definition Description P2 1 9 16VIN Power supply 12V 16VAC DC P2 2 GND Earth Ground P2 3 ALARM Alarm output 5VDC 0VDC is normal status P2 4 RTE Request to Exit P2 5 SENSOR Door Sensor P2 ...

Страница 7: ...S485 A RS485 B External reader BUZZER External reader LED External reader Data 0 External reader Data 1 External reader Ground External reader Power Fail Secure Fail Safe 12VDC PBT 800 AS 500 Must install a Diode DG 2000US 2100EU Controller 1 2 3 4 5 6 7 8 Alarm out at 5 VDC Normal is 0 VDC Must install a Diode 1 2 3 4 5 6 7 8 Power Supply Unit Exit Button Exit Button Wiring diagram INPUT 100 240V...

Страница 8: ... on Setup system basic parameters Enter the program mode Reset to factory setting Change master password Change door common access password Setup operation mode Setup current time Setup Electrified lock release time Setup time interval function option Setup time interval for No password entry needed Setup electrified lock release time interval function Setup time interval for alarm disabled functi...

Страница 9: ...assword or Door Access PIN for entry Default Enter 05 Require a Door Access PIN for entry only Install DG 2000US or DG 2100EU controller at indoor area and install GEM Optional Reader at outdoor area Secure Mode Enter 02 For DG 2000US or DG 2100EU requires a Card only No Common Access Password for entry required For outdoor GEM Optional Reader requires a Card AND Common Access Password for entry E...

Страница 10: ...efore weekend and holiday Setting Time Interval For Disabling Alarm During this period alarm output is not available Setting time interval 1 Press 88 From HHMM To HHMM Setting time interval 2 Press 89 From HHMM To HHMM Enable Time Interval Function of NO Password Entry Needed Option Enable Press 34 Enable the function Disable Press 44 Default Setting Enable Time Interval Function of Electrified Lo...

Страница 11: ...again to exit the program mode Add User Card Press 11 Location ID use user card or enter 10 digit card number and Location ID is from NOTE If continue adding a user card no need to press 11again only enter Location ID use user card or enter 10 digits card number and If the location ID has cardholder record the reader will get 4 beeps continue or return to program mode by press Press to return to p...

Страница 12: ...and NOTE If continue deleting a user card no need to press 21 again only use user card or key in 10 digit card number and Press to return to program mode and hear 2 beeps press again to exit the program mode Delete Door Access PIN Press 22 Door Access PIN Door Access PIN NOTE If continue deleting a user card no need to press 22 again only enter Door Access PIN Door Access PIN Press to return to pr...

Страница 13: ...___________________________________________________________ Version 1 05 22 2015 Gianni Industries Inc Page 13 of 17 7 Users List IMPORTANT NOTICE Please update the card numbers and PINs for reference Card Number Table 2000 Cardholders Location ID Card Number User Name Expiration Date 1 2 3 1999 2000 Door Access PIN Table 200 PINs Location ID PIN User Name Expiration Date 2001 2002 2003 2199 2200 ...

Страница 14: ... master password d No need to enter leading zero for any kind of password complete entry by pressing the key e The 200 door access PINs are capable from 1 to 6 digits f Electrified lock release time shall be shorter than the door ajar time g We suggest that user update the device clock time by monthly h If a user does not return the card to you please delete the access authority by the location ID...

Страница 15: ...ypad K Reader with keypad CSN Card serial number DG 2000K SR Slim reader without keypad SK Slim reader with keypad DG 2000SR Optional Accessories Part Number Description P CB 10AE P CB 8 P CB 6 P CB 4 P CB 2 S PL UT P PL UR 3P PSM 25T PSM 26T 10 Conductors 24 Gauges 8 Conductors 24 Gauges 6 Conductors 24 Gauges 4 Conductors 22 Gauges 2 Conductors 22 Gauges 2 way butt terminal 0 4 0 9mm wire 3 way ...

Страница 16: ...Conductors Standard 24 Gauges Available Crimp Butt Splice Terminals 2 way butt terminal P CB 10AE Available Power Supply Units Power Cables S PL UT S PL UR 3P 0 4 0 9mm wire 3 way butt terminal 0 4 0 9mm wire Power Supply Unit PSM 25T PSM 26T Power Supply Unit with Cableit US Standard Cable EU Standard Cable UK Standard Cable Special designed with re locking timers for electrified locks Field sele...

Страница 17: ...___________________________ _______________________________________________________________________________________________________________ Version 1 05 22 2015 Gianni Industries Inc Page 17 of 17 Main PROX Reader Controllers DG 2000US DG 2100EU DG 2000R DG 2100R DG 2100K Optional Readers DG 2000K DG 2000SR DG 2000SK ...

Отзывы: