background image

Installation Instructions

High-spec Wired Remote Controller

Model No. 

CZ-RTC5B

English

Read through the Installation Instructions before you proceed 

with the installation.

In particular, you will need to read under the “Safety 

Precautions” on page 3.

WEB-ACXF60-26852-EN

H0318-20921

Panasonic Corporation
http://www.panasonic.com

Contents

 

Part Names ....................................... 2

 

Supplied accessories ...................... 2

 

Safety Precautions ........................... 3

 

Speci

fi

 cations ................................... 4

 

Installation Precautions................... 5

 

Mounting ........................................... 7

Exposed type ................................ 7
Embedded type ............................ 8

 

Setting ............................................... 9

Language ..................................... 9
Clock ............................................ 9
Controller name ............................ 9
Service contact ........................... 10
RC. setting mode .........................11
Detailed settings ..........................11
Auto address .............................. 12
Set elec. consumption ................ 12

 

Con

fi

 rming Information ................. 13

 

Test Operation ................................ 14

Содержание CZ-RTC5B

Страница 1: ...ns on page 3 WEB ACXF60 26852 EN H0318 20921 Panasonic Corporation http www panasonic com Contents Part Names 2 Supplied accessories 2 Safety Precautions 3 Specifications 4 Installation Precautions 5...

Страница 2: ...lluminates during operation Blinks during alarm 8 Start Stop button Starts Stops operation 3 Enter button Fixes the selected content 4 Energy saving button Switches Energy saving Normal operation Rig...

Страница 3: ...t breaker of the units before installation Ask your dealer or professionals for installation and electric work This controller shall be installed in accordance with National Wiring Regulations Connect...

Страница 4: ...ature Humidity range 0 C to 40 C 20 to 80 no condensation Indoor use only Power Source DC16 V supplied with indoor unit Clock precision 30 seconds month at normal temperature 25 C Adjust periodically...

Страница 5: ...e Remote control wiring Wiring diagram 1 2 R1 R2 Indoor unit Terminals for RC wiring RC RC wiring field supply No polarity Type of wiring Use cables of 0 5 to 1 25 mm2 Total wire length 500 m or less...

Страница 6: ...ntroller to Main and the other to Sub for Main sub for Setting P 11 When using the remote controllers in combination set this unit to Main CZ RTC2 CZ RTC4 CZ RE2C2 CZ RELC2 Using 1 indoor unit R1 R2 1...

Страница 7: ...oy the PCB 2 Mount to the wall Flat blade screwdriver Insert the driver and slightly turn Bottom case Mounting Exposed type 1 3 2 Mount the top case Align the claws of the top case and then align the...

Страница 8: ...en align the claws of the bottom case Avoid the wire being caught Claw 2 places Screw Supplied Hole for screw Claw 2 places Mount the bottom case to the wall Pass the wire through the hole in the cent...

Страница 9: ...Note To return to the previous screen Press 1 Press Controller name 2 Select Initial settings 3 Select the item to set Language 4 Set Default setting English Clock 4 Set Repeat 5 4 2018 Controller na...

Страница 10: ...s Up to 16 characters Space is included in the number of characters To change the character type Select the character type with and press To enter space Select Space with and press To delete 1 charact...

Страница 11: ...actory setting 0001 Not displayed 0002 Not displayed password Detailed settings 3 Set Select the indoor unit number Code no and Set data Repeat Indoor unit number Set data Code no 4 Press After Select...

Страница 12: ...address is set and 90 seconds or more have passed Set elec consumption 3 Set Select the power supply voltage of outdoor units 4 Select YES Note Set the power supply voltage of outdoor units to calcula...

Страница 13: ...f the remote controller indoor units and outdoor units 3 Select Select the unit number 4 Confirm the content Pressing will return to the Maintenance func screen Service check This displays the alarm h...

Страница 14: ...lay disappears The test operation can be performed in Heat or Cool mode Temperature cannot be changed The test operation mode is automatically turned o in 60 minutes To prevent continuous test operati...

Страница 15: ...Panasonic Corporation 2018 2021...

Отзывы: