Before operating the unit, read these operating instructions thoroughly and keep them for future 
reference.

81405230169000

G0114-0

CV6233312187

WEB-URL 

Panasonic Corporation

 

 Website:http://panasonic.net/

Содержание CZ-RTC3

Страница 1: ...ired Remote Controller Model No CZ RTC3 Installation Instructions Separately Attached ENGLISH Before operating the unit read these operating instructions thoroughly and keep them for future reference...

Страница 2: ...he menu screen P 10 Operation indicator Illuminates during operation Blinks during alarm Start Stop button Starts Stops operation Enter button Fixes the selected content Press centre No glove No pen E...

Страница 3: ...WARNING Do not use this appliance in a potentially explosive atmosphere Do not operate with wet hands Do not wash with water In case of malfunction of this appliance do not repair by yourself Contact...

Страница 4: ...ce to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television receptio...

Страница 5: ...NOTICE The English text is the original instructions Other languages are translation of the original instructions CONTENTS Part Names 2 Control panel 2 Safety Precautions 3 Part Names 6 Screen displa...

Страница 6: ...P 33 Setting information icon When checking the meanings of all icons P 39 Operation guide P 7 Cursor Operation mode Set temperature Fan speed Flap Operation lock is functioning P 33 To cancel lock Pr...

Страница 7: ...hibited Switching to Auto mode is also prohibited Remote control operation is restricted by a central control device ON OFF timer is set P 14 Weekly timer is set P 15 Energy saving operation is in pro...

Страница 8: ...the actual flap angle Pressing after recovery from mains power failure will resume operation with the contents before mains power failure has occurred If no operation is performed for a certain perio...

Страница 9: ...Fan Auto Set temperature Press When the cursor is not visible Cool Dry 18 C to 30 C Heat 16 C to 30 C Auto 17 C to 27 C Fan speed Press Flap Press 2 times Flap Setting for Each Indoor Unit P 12 Swing...

Страница 10: ...s screen Press When no operation is performed in each setting screen for several minutes The display returns to the top screen 2 Select the menu item To turn the page Press Selectable menus 1 to 13 Fo...

Страница 11: ...elapsed even if the temperature is changed P 24 Temp range Restricts the temperature range that can be set P 25 Auto shutoff Sets the auto shutoff timer P 26 Schedule peak cut Determines the time zone...

Страница 12: ...ss 2 times 2 Select FLAP 3 Select the indoor unit to set ALL All units connected to the remote controller e g unit ALL 1 1 1 2 to 1 8 4 Select the flap direction Press 2 times to finish Pressing or du...

Страница 13: ...he previous screen Press To return to the top screen Press 2 times 2 Select Lock indiv flap 3 Select the indoor unit to set e g 1 1 1 2 to 1 8 4 Select the air outlet The air outlet No changes accordi...

Страница 14: ...he air conditioner according to the meeting start timing 1 Display the menu screen To return to the previous screen Press To return to the top screen Press 2 times 2 Select ON OFF timer 3 Select the t...

Страница 15: ...with the specified temperature TEMP Sets the temperature to the specified temperature during operation Combination examples 1 Stop operation earlier on No overtime work day 8 00 17 00 8 00 22 00 ON ON...

Страница 16: ...times 2 Select Weekly timer 3 Enable the Weekly timer Select the item with and select enable disable with 4 Select for all days when the timer is used Repeat Select the days with and select enable di...

Страница 17: ...temperature during operation 9 Set the temperature Only for operations other than ON OFF 10 Confirm the setting content Confirm and press Press 2 times to finish To register additionally Repeat from s...

Страница 18: ...as follows To change the setting following steps 7 to 10 on page 17 set the time timer operation and temperature and confirm the content To delete the setting select YES Press 2 times to finish To ch...

Страница 19: ...ly the same schedule to multiple days 1 Display the menu screen To return to the previous screen Press To return to the top screen Press 2 times 2 Select Weekly timer 3 Select Timer copy 4 Select the...

Страница 20: ...filter cleaning time 4 Confirm the operation time to the next cleaning Press 2 times to finish When cleaning is immediately necessary The screen shown on the right is displayed Clean the filter See o...

Страница 21: ...1 EN Note Depending on the model Filter info cannot be used In this case a message is displayed as shown on the right When the cleaning time comes the icon shown on the right appears on the top screen...

Страница 22: ...revious screen Press To return to the top screen Press 2 times 2 Select the item to set Quiet operation 3 Enter the password Repeat 4 Set Select enable disable to Select the item with and select with...

Страница 23: ...ght Using the quiet operation function may deteriorate the performance to reduce the operation sound The power consumption shows an approximate calculation result which may differ from the measurement...

Страница 24: ...ot be set 1 Display the menu screen To return to the previous screen Press To return to the top screen Press 2 times 2 Select Energy saving 3 Select the item to set Temp auto return 4 Select the item...

Страница 25: ...in series Repeat from step 4 without pressing Note Temp auto return When Return type is set to Saving this functions only when the temperature set in step 5 saves more energy than the changed temperat...

Страница 26: ...operation automatically e g 60 min ON OFF 21 00 22 08 Detect Detect Detect 23 00 9 00 60 min 60 min 60 min Closing time Opening time Auto shutoff in effect Leaves the shop without turning off A C If o...

Страница 27: ...is activated 5 Set hour minute Press 2 times to finish End time Time when Auto shutoff stops 5 Set hour minute Press 2 times to finish Timer Time interval to detect operation status after Stop time 5...

Страница 28: ...the last screen Press To return to the top screen Press 2 times 2 Select Energy saving 3 Select Schedule peak cut 4 Enter the password Repeat 5 Set Select enable disable to 6 Select Set schedule 7 Cha...

Страница 29: ...set in series Repeat from step 4 without pressing To change Select the field to change in step 7 above Select Change Following the above steps 8 to 9 select the start time end time and operation capac...

Страница 30: ...nu screen To return to the previous screen Press To return to the top screen Press 2 times 2 Select Energy saving 3 Select Repeat off timer and set to 4 Set the timer to stop Press 2 times to finish 1...

Страница 31: ...31 EN Outing Function This function prevents the room temperature from rising too high or dropping too low when no one is in the room due to outing etc...

Страница 32: ...creen To return to the previous screen Press To return to the top screen Press 2 times 2 Select Outing function 3 Select Select enable disable and set to 4 Select Set lower upper limit temp 5 Set the...

Страница 33: ...en Press 2 times 2 Select Initial settings 3 Select the item to set Clock 4 Set the date and time Repeat Clock type 4 Select the type to display Press 2 times to finish AM PM 24 h Operation lock 4 Sel...

Страница 34: ...Select Initial settings 3 Select Controller name 4 Enter the name Repeat the same procedure for all characters Up to 16 characters Space is included in the number of characters To change the character...

Страница 35: ...en To return to the previous screen Press To return to the top screen Press 2 times 2 Select Initial settings 3 Select the item to set Touch sound 4 Press 2 times to finish ON OFF Contrast 4 Press 2 t...

Страница 36: ...o the previous screen Press To return to the top screen Press 2 times 2 Select Initial settings 3 Select the item to set 4 Enter the password as necessary Repeat Select the number with and move to the...

Страница 37: ...however when the remote controller sensor is selected for the temperature sensor setting the Main sensor controls the operation Vent output Set When the air conditioner is turned ON OFF the connected...

Страница 38: ...ation Setting 1 Display the menu screen To return to the previous screen Press To return to the top screen Press 2 times 2 Select Ventilation 3 Select Ventilation ON OFF 4 Select ON or OFF Press 2 tim...

Страница 39: ...icons 1 Display the menu screen To return to the previous screen Press To return to the top screen Press 2 times 2 Select Setting list 3 Select the item Only icons currently being displayed on the scr...

Страница 40: ...ON OFF timer is set P 14 Weekly timer is set P 15 Energy saving operation is in process P 8 The operation capacity of the outdoor unit is restricted Schedule peak cut is set P 28 Temp auto return is s...

Страница 41: ...indoor unit No If any of the following alarm indications appears stop operation once and restart approx 1 minute later Alarm indication off E04 E06 P10 P20 H06 If the indication does not reappear use...

Страница 42: ...ndoor unit Clock Precision 30 seconds month at normal temperature 25 C Adjust periodically Holding time 72 hours When fully charged Approx 8 hours are required for full charge Number of connected indo...