Official GSK Agents in South Africa
Tel: +27 11 626 2720, [email protected]
GSK980TDi Turning CNC System User Manual
44
Ⅰ
Programming
mode N_ is omitted, at the time, the system only counts and doest not alarm for the output.
Note 3: Other commands between G10 L3 and G11 are ignored.
Note 4: Running the tool life preset program (such as O0020) completely clear all previous life data and
preset the life data according to the program requirements.
Note 5: Prevent the life data from being modified manually when the part programs are running until the run
state stops (except for running the tool life preset programs).
Note 6: All tool life data is stored when power-down.
2) Input tool life management data in the tool life management window
Input directly the tool life management data in tool compensation- >tool life window in MDI
mode, parameter switch ON and 3-level operation limit.
A. alter data:
In tool compensation -> tool life window, press
to move the tool to the life position, input
directly data, such as 500, press
to confirm the input. Press
to
complete data input (tool offset, life) .
B. Inserting data:
Insert any serial number in the current page, press
――
>[
01
~
08
]
――
>
, insert
a new line, and the initial value definition is as follows:
Serial number
Tool offset
Life
Used
Mode
State
N 0000
0
0
0
Over
a) Insert the front and the previous serial number moves backward.