![GSK 980TDi User Manual Download Page 479](http://html1.mh-extra.com/html/gsk/980tdi/980tdi_user-manual_2275219479.webp)
Official GSK Agents in South Africa
Tel: +27 11 626 2720, [email protected]
Chapter 3 Parameters
463
Ⅲ
Connection
[
Data unit
]
Setting unit
Data unit
Metric machine
mm/min
Inch machine
0.1inch/min
[
Data range
]
10
~
99999999
0 2 3
LINTn
[
Data type
]
Word
axis
[
Data meaning
]
Acceleration/deceleration time constant value
[
Data unit
]
ms
[
Data range
]
10
~
4000
0 2 7
FEDM
[
Data meaning
]
Upper limit of cutting feedrate
[
Data unit
]
Setting unit
Data unit
Metric machine
mm/min
Inch machine
0.1inch/min
[
Data range
]
IS-B
IS-C
Metric machine
10
~
30000 10
~
30000
Inch machine
5
~
11600 10
~
11600
0 2 9
FEEDT
[
Data meaning
]
Acceleration/deceleration
time
constant during cutting feed and manual feed
[
Data unit
]
ms
[
Data range
]
0
~
4000
0 3 0
FEDFL
[
Data meaning
]
The starting speed of cutting feed
[
Data unit
]
Setting unit
Data unit
Metric machine
mm/min
Inch machine
0.1inch/min
[
Data range
]
IS-B
IS-C
Metric machine
0
~
8000 0
~
8000
Inch machine
0
~
3000 0
~
3000
0 3 1
JOGSPEED
[
Data meaning
]
Set speed when manual feedrate override is 100%
[
Data unit
]
Setting unit
Data unit