Chapter 4 MPG/Step Operation
247
Ⅱ
Operation
4.2.1 Increment Selection
Press
key to select the move increment, the increment will be shown in the
window. When the BIT7(SINC) of PLC K016 is 1, step
is inactive; when BIT7 is 0,
are all active. For example, to press
key, the window is shown as
follows:
4.2.2 Moving Axis & Direction Selection
In MPG mode, press
,
,
,
,
key, the corresponding axis will be
selected. For example, press
key and the window is shown below:
The MPG feed direction is defined by its rotation direction. Generally, the MPG CW is for positive
feed, and CCW for negative feed. In case of that MPG CW is for negative feed, CCW for positive feed,
it may exchange the A, B signals of the MPG terminals. Bit0
~
Bit4 of NO. 013 selects the feed
direction of MPG rotation.