Chapter 12 U Operation Function
345
Ⅱ
Operation
Select the update system by
soft button, and confirm the update state by
.
Note: Page update can be entered above the 2-level authorities.
12.5 Notes
The user should pay more attention to the followings during executing the data backup/resume
operation:
1) Need more than the 2
nd
grade password(including the 2
nd
grade) to resume more than
(including be equal to) 9000 part programs;
2) It is necessary to connect the GSKLINK bus normally when the back up/recovery of the servo
parameter is performed;
3) Backup/resume operation must be in MDI mode;
4) When the user executes the data backup operation, the system automatically replaces all files
in “U:\gsk980TDi_backup\user”, the user should save them as when they cannot be replaced;
5) Stop part programs running before data backup/resume;
6) They must not stop unless the data backup/resume operation is completed;
7) The system is turned on again after the data resume is done.