Official GSK Agents in South Africa
Tel: +27 11 626 2720, [email protected]
Chapter 3 Parameters
471
Ⅲ
Connection
1 2 2
REF3_COORDn
1 2 3
REF4_COORDn
[
Data type
]
Word axis
[
Data meaning
]
REF1_COORDn machine coordinates of 1
st
reference point of each axis;
REF2_COORDn machine coordinates of 2
nd
reference point of each axis;
REF3_COORDn machine coordinates of 3
rd
reference point of each axis;
REF4_COORDn machine coordinates of 4
th
reference point of each axis.
[
Data unit
]
Set unit
IS-B
IS-C
Metric input
0.001 mm
0.0001 mm
Inch input
0.0001 inch
0.00001 inch
[
Data range
]
-99999999
~
99999999
3.2.6 Thread Function
1 7 4
THDTLMOD THDA
CKSPD
Bit2 1:Thread tailing mode tailling according angle;
0:Thread tailing mode rapid tailing.
Bit1 1:Thread cut is exp. acc&dec
0:Thread cut is lin. acc&dec
Bit0 1:Whether detect the spindle speed is too slow in thread cutting don't detect\
0:Whether detect the spindle speed is too slow in thread cutting do detect
0 1 9
THDCH
[
Data meaning
]
thread run-out length in thread cutting.
[
Data range
]
0
~
225
Thread run-out width=THDCH×0.1×thread lead
0 2 6
THRDT
[
Data meaning
]
short acceleration/deceleration time constant in thread run-out.
[
Data unit
]
ms
[
Data range
]
0
~
4000
0 2 8
THDFL
[
Data meaning
]
X, Z initial speed in thread cutting.
[
Data unit
]
Set unit
Data unit
Metric machine
mm/min
Inch machine
0.1inch/min
[
Data range
]
6
~
8000
1 0 6
THD_SPD_VAR
[
Data meaning
]
Spindle fluctuation alarm limit in threading (not detect spindle fluctuation alarm if set
to 0)