Chapter 3 Parameters
473
Ⅲ
Connection
[
Data range
]
10
~
9999
0 6 7
SFTREV
[
Data meaning
]
output voltage in spindle gear shifting.
[
Data unit
]
mV
[
Data range
]
0
~
10000
0 6 8
SJOGREV
[
Data meaning
]
spindle rotary axis speed in Manual (MPG) mode.
[
Data unit
]
r/min
[
Data range
]
0
~
3000
0 6 9
ENCODER_CSE
[
Data type
]
Word
spindle
[
Data meaning
]
The corresponding spindle encoder number of each spindle
。
0: without installing the encoder;
1: Spindle revolving signal comes from the encoder interface 1;
2: Spindle revolving signal comes from the encoder interface 2;
3: Spindle revolving signal comes from the GSKLINK bus
[
Data range
]
0
~
3
0
7
0
ENCODER_CNT
[
Data meaning
]
spindle encoder lines.
[
Data unit
]
line/r
[
Data range
]
100
~
10000
0
7
2
SAR_DELEY
[
Data meaning
]
spindle speed arrival signal delay check time.
[
Data unit
]
ms
[
Data range
]
0
~
4080
0
7
3
SPMOTORMAX
[
Data meaning
]
max. clamp speed of spindle motor speed.
[
Data unit
]
r/min
[
Data range
]
0
~
4095
Setting value=
(
max. clamp speed of spindle motor/its max. speed
)
×4095.
0
7
4
SPMOTORMIN
[
Data meaning
]
min. clamp speed of spindle motor speed.
[
Data unit
]
r/min
[
Data range
]
0
~
4095
Setting value=
(
min. clamp speed of spindle motor/its min. speed
)
×4095.