![GSK 980TDi User Manual Download Page 34](http://html1.mh-extra.com/html/gsk/980tdi/980tdi_user-manual_2275219034.webp)
Official GSK Agents in South Africa
Tel: +27 11 626 2720, [email protected]
GSK980TDi Turning CNC System User Manual
18
Ⅰ
Programming
1.5 Program Run
1.5.1 Sequence of Program Run
Running the current open program must be in Auto mode. GSK980TDi cannot open two or more
programs at the same, and runs only program any time. When the first block is open, the cursor is
located in the heading of the first block and can be moved in Edit mode. In the run stop state in Auto
mode, the program starts to run by the cycle start signal (
is pressed or external cycle start
signal)from a block pointed by current cursor, usually blocks are executed one by one according to
their programming sequence, the program stops running till executing M02 or M30. The cursor moves
along with program running and is located at the heading of the current block. Sequence and state of
program running are changed in the followings:
z
The program stops running after pressing
or emergent stop button;
z
The program stops running when the system or PLC alarms;
z
The program runs and single block stops (the program run stops after the current block runs
completely) in Edit, MDI mode, and then a block pointed by the current cursor starts running
after the system switches into Auto mode,
is pressed or external cycle start signal is
switched on;
z
The program stops running in Manual(Jog), Handwheel (MPG), Single Block, Program
Reference Point Return, Machine Reference Point Return mode and it continuously runs
from current position after the system is switched into Auto mode and
is pressed or
the external cycle start signal is switched on;
z
The program pauses after pressing
or the external cycle start signal is switched off,
and it continuously runs from current position after pressing
or the external cycle
start signal is switched on;
z
When Single Block is ON, the program pauses after every block is executed completely, and