![GSK 980TDi User Manual Download Page 468](http://html1.mh-extra.com/html/gsk/980tdi/980tdi_user-manual_2275219468.webp)
Official GSK Agents in South Africa
Tel: +27 11 626 2720, [email protected]
GSK980TDi Turning CNC System User Manual
452
Ⅲ
Connection
[
Data range
]
0, 20~27, 30~37
1 4 0
TWEAR_MAX
[
Data meaning
]
+ or – limit of each input wear in TOOL OFFSET&WEAR interface
[
Data unit
]
Setting unit
IS-B
IS-C
Metric input
0.001 mm
0.0001 mm
Inch input
0.0001 inch
0.00001 inch
[
Data range
]
IS-B IS-C
Metric input
1
~
99999 1
~
999999
Inch input
1
~
99999 1
~
999999
1 4 1
AUTO_OFFSET_FEED
[
Data meaning
]
Feedrate
in
automatic
tool offset measure
[
Data unit
]
Setting unit
Data unit
Metric machine
mm/min
Inch machine
0.1inch/min
[
Data range
]
IS-B
IS-C
Metric machine
15
~
1000 15
~
1000
Inch machine
7
~
375 7
~
375
1 4 2
AUTO_OFFSET_Y_X
1 4 3
AUTO_OFFSET_Y_Z
[
Data meaning
]
X(AUTO_OFFSET_Y_X)
,Z(AUTO_OFFSET_Y_Z)
γ
values in automatic tool
offset
[
Data unit
]
Setting unit
IS-B
IS-C
Metric machine
0.001 mm
0.0001 mm
Inch machine
0.0001 inch
0.00001 inch
[
Data range
]
1
~
9999999
Note: X setting value is the radius in diameter or radius programming
1 4 4
AUTO_OFFSET_E_X
1 4 5
AUTO_OFFSET_E_Z
[
Data meaning
]
AUTO_OFFSET_E_X
(
X
)
,AUTO_OFFSET_E_Z
(
Z
)
ε
values in automatic tool
offset
[
Data unit
]
Setting unit
IS-B
IS-C
Metric machine
0.001 mm
0.0001 mm
Inch machine
0.0001 inch
0.00001 inch